1128500
WPC 2000 User Manual
3-16
Initialization, Setup, and Checkout
Setting the Stop-time Limit
To set the Stop-time Limit, do the following:
1.
Check to make sure that option switch 7 on switch block S101 on the WPC 2000 Main
Processor board is set to OFF to enable changes to the Stop-time Limit (see page 3-29).
2.
With power on to the WPC 2000 and the press in “Inch” mode, press the Reset/Select
button repeatedly until the “Stop Time Limit” indicator becomes lit (see Figure 3-7). The
LED display shows the last Stop-time Limit you set or, if you have not previously set the
Stop-time Limit, it shows the factory setting of 500 mS.
3.
Adjust the Stop-time Limit by turning the WPC Settings key switch to “+”
(counterclockwise) to increase the value or to “–” (clockwise) to decrease the value. The
Stop-time Limit setting increases or decreases in 10 mS increments.
INCORRECT SAFETY DISTANCE DUE TO INCORRECT STOP TIME
• Determine and enter the correct Stop-time Limit when you set up your WPC 2000.
• Perform a 90° Stop Test any time you change the Stop-time Limit of WPC 2000. (See Determining
the 90° Stop Time, page 3-17.) Base the Stop-time Limit on the actual Stopping Time.
• Recalculate the safety distance based on the new Stop-time Limit and adjust or reinstall
safeguarding devices according to the new safety distance (see Calculating the Safety
Distance, page 3-19).
Failure to comply with these instructions will result in death or serious injury.
PREVENT CHANGES TO STOP-TIME LIMIT WHEN SETTINGS KEY IS PRESENT
Use option switch 7 to prevent anyone from making changes to the Stop-time Limit (see Switch 7 –
Disabling Access to Stop-time Limit and Auto Carry-up Angle Settings, page 3-29).
Failure to comply with these instructions will result in death or serious injury.
Figure 3-7. WPC 2000 Display Showing Stop-time Limit Value
DANGER
!
DANGER
!
With Stop Time Limit segment
selected, turn WPC Settings
key switch to + to increase
displayed value and to -
to decrease value
BRAKE WARNING
INTERRUPTED STROKE
TOP STOP ANGLE
AUTO CARRYUP
STOP TIME LIMIT
MICRO-INCH
STOPPING TIME
STOPPING ANGLE
90
°
STOP TEST
COUNTER
COUNTER PRESET
ANGLE / SPM
cam on angle
cam off angle
Summary of Contents for wpc 2000
Page 91: ...1128500 WPC 2000 User Manual 2 64 Installation ...
Page 191: ...1128500 WPC 2000 User Manual 5 22 Troubleshooting ...
Page 209: ...1128500 WPC 2000 User Manual A 18 Extracts from OSHA and ANSI ...
Page 225: ...1128500 WPC 2000 User Manual G 6 Glossary ...
Page 231: ......
Page 232: ......
Page 233: ......
Page 234: ......
Page 235: ......
Page 236: ......
Page 237: ......
Page 238: ......
Page 239: ......
Page 240: ......
Page 241: ......
Page 242: ......
Page 243: ......
Page 244: ......
Page 245: ......
Page 246: ......
Page 247: ......
Page 248: ......
Page 249: ......
Page 250: ......