WPC 1000 User Manual
1125100
Installation
2-37
Making Wiring Connections to Cam Relays
To connect the cam relays on the Cam Output board to your equipment, do the following:
1.
Remove the TB2 (for cam channel 1) and TB3 (for cam channel 2) connectors from the
cam output board and wire them as follows, referring to Figure 2-19:
•
Connect one wire to the terminal labelled “C”
•
Connect the other wire to the terminal labelled “N/O” if you want your equipment to be
“on” during the cam angle interval set in WPC 1000
or
Connect the other wire to the terminal labelled “N/C” if you want your equipment to be
“on” except during the cam angle interval set in WPC 1000
2.
Plug TB2 and TB3 back into the Cam Output board.
TRIM UNUSED WIRES
If your installation does not require all the wires in the cable to be used, trim the unused wires,
cutting them flush with the ends of the cable jacket.
NON-SAFETY OUTPUTS USED FOR SAFETY FUNCTIONS
Use cams for non-safety functions only, such as convenience in automation. They cannot protect
personnel from a moving hazard.
Failure to comply with these instructions will result in death or serious injury.
Figure 2-19. Connectors TB2 and TB3 on Cam Output Board
Generally, you use the N/O terminal so that equipment is “off” except when you use WPC
1000 to turn it “on.” Use the N/C terminal only if it is more practical to do the reverse.
NOTICE
DANGER
!
N/O
C
N/C
N/O
C
N/C
N/O
C
N/C
N/O
C
N/C
CHAN 1
CHAN 2
TB3
TB2
[NOT USED]
[NOT USED]
TB4
TB5
NOTICE
Summary of Contents for WPC 1000
Page 17: ...1125100 WPC 1000 User Manual xii Table of Contents ...
Page 99: ...1125100 WPC 1000 User Manual 2 72 Installation ...
Page 207: ...1125100 WPC 1000 User Manual A 18 Extracts from OSHA and ANSI ...
Page 217: ...1125100 WPC 1000 User Manual G 6 Glossary ...
Page 223: ......
Page 224: ......
Page 225: ......
Page 226: ......
Page 227: ......
Page 228: ......
Page 229: ......
Page 230: ......
Page 231: ......
Page 232: ......
Page 233: ......
Page 234: ......
Page 235: ......