16 89005779
10.2 As required
FI fault-current circuit-breaker:
Check the required FI-residual current operated device for faults regularly according to
the regulations by pressing the test button.
Changing the detergent type (liquid product)
If changing to a different detergent type (even one by the same manufacturer), you must rinse the suction
and pressure hoses with fresh water before connecting the new detergent container.
Otherwise, the mixing of different types of detergent will cause crystallisation, which may result in a break-
down of the dosing pump.
Failure to observe this rule will lead to the loss of guarantee and product liability claims vis-à-vis Winterhalter
Gastronom GmbH.
Procedure:
•
Remove the suction stick from the empty detergent container and place it in a container filled with fresh
water.
•
Drain the machine completely and refill it. Then drain it again, since no detergent has been dispensed
during this process.
•
Insert the suction stick in the new detergent container
Descaling
Drain machine.
Interrupt detergent supply: Remove suction pipe from the detergent canister.
Re-fill machine.
Addition of the descaling solution according to manufacturer’s instructions.
Observe the printed safety instructions.
Trigger intensive programme once or twice (max. 10 minutes circulation). This loosens the coating of scale.
Drain machine.
Never leave the descaling solution in the machine for a period of several hours.
Put detergent supply into operation again.
Re-fill machine.
Operate machine twice more in intensive programme mode.
Drain machine or use for the current wash programme.