page 9 of 24
Document: U99_001
4.3.1.6
Base frame
According to customer request, the aggregate is mounted on base frame.
4.4 Details on installation site
4.4.1
Space requirement for operation and maintenance
The pump aggregat must be installed in a way that enables to exchange components or the complete unit. If the aggregate
is heavy, facilities adapted to the weight are to be provided in order to safe hang-in support of lifting devices and other
auxiliaries. Provide appropriate corridors for the transport.
4.4.2
Admissible environmental conditions
Pay attention to dry, frost-proof, vibration free istallation of the pumps and pump aggregates. Ambient temperatures below
5°C and higher than 40°C must be avoided. Variations are available on inquiry.
4.4.3
Underground, fundament, wall
Basements must be designed so, that pump respectively the complete pump aggregat can be built up in a safe way and
without stresses. Pay attention to the fact that no vibrations are passed onto the pump or pump aggregate via fundament.
5.4. Pipe works
4.4.4
Auxiliary connections
Order related, see order confirmation and delivery note
WSCA 600
Grease connection for gland packing
Grease connection for slide bearing
4.5 Emission values
The noise expectancy values during operation of the Norm-Pumps are, according to size, operation point and motor, of a
sound pressure level between 65dB und 100 dB.
Hazards by noise emissions
Use noise protection (personal protective gear)
4.6 Measurements and weights
The measurements of the supplied product are stated in dimensional drawing, enclosed to this manual.
The weight, applicable for the supplied pump/unit is stamped on name plate.