Winsen MQ135 Manual Download Page 5

 

Zhengzhou Winsen Electronics Technology Co., Ltd               

www.winsen-sensor.com

 

Tel: 86-371-67169097/67169670    Fax: 86-371-60932988                                Email: 

[email protected]

 

 

 

                                                                                                                                                           

                                                                                                                                            

 

                                            

 

Cautions 

1 .Following conditions must be prohibited 

1.1 Exposed to organic silicon steam                                 

Sensing  material  will  lose  sensitivity  and  never  recover  if  the  sensor  absorbs  organic  silicon  steam. 
Sensors  must  avoid  exposing  to  silicon  bond,  fixature,  silicon  latex,  putty  or  plastic  contain  silicon 
environment. 

1.2 High Corrosive gas 

If the sensors are exposed to high concentration corrosive gas (such as H

2

S, SO

X

, Cl

2

, HCl etc.), it will 

not only result in corrosion of sensors structure, also it cause sincere sensitivity attenuation.   

1.3 Alkali, Alkali metals salt, halogen pollution 

Fig6.Responce and Resume

 

Fig5 shows the changing of V

RL 

in the process of putting 

the sensor into target gas and removing it out.

 

Fig5.Sensitity Curve

 

Fig5 shows the V

RL

 in H2 gas with different concentration. 

The resistance load R

L

 is 4.7 KΩ and the test is finished in 

standard test conditions.

 

 

Fig7.long-term Stability

 

Test is finished in standard test conditions, the abscissa is observing time and the ordinate is V

RL

 

 

400ppm H

(RL=4.7k) 

Concentration (ppm) 

Time (s) 

Time (day) 