Basic Circuit 

 

 

 

 

 

 

 

 

 

 

Fig2. MQ135 Test Circuit 

Instructions: 

The  above  fig  is  the  basic  test  circuit  of  MQ135.The  sensor  requires  two  voltage  inputs: 

heater  voltage  (V

H

)  and  circuit  voltage(V

C

).  V

H

  is  used  to  supply  standard  working  temperature  to  the 

sensor and it can adopt DC or AC power, while V

RL

 is the voltage of load resistance R

which is in series with 

sensor. Vc supplies the detect voltage to load resistance R

L

 and it should adopts DC power.

 

Description of Sensor Characters

 

           

 

 

 

 

Fig3.Typical Sensitivity Curve

 

The  ordinate  is  resistance  ratio  of  the  sensor  (Rs/R

0

),  the 

abscissa is concentration of gases. Rs means resistance in 

target  gas  with  different  concentration,  R

means 

resistance  of  sensor  in  clean  air.  All  tests  are  finished 

under standard test conditions. 

 

Fig4.Typical temperature/humidity characteristics

 

The  ordinate  is  resistance  ratio  of  the  sensor  (Rs/Rso).Rs 

means  resistance  of  sensor  in  400ppm  H

2

  gas  under 

different  tem.  and  humidity.  Rso  means  resistance  of  the 

sensor in 400ppm H

2

 gas under 20

/55%RH. 

 

H

2

 

Air 
NH

3

 

Toluene 

Concentration (ppm) 

Reviews: