Zhengzhou Winsen Electronics Technology Co., Ltd
Tel: 86-371-67169097/67169670 Fax: 86-371-60932988 Email:
Leading gas sensing solutions supplier in China!
1.3 Alkali, Alkali metals salt, halogen pollution
The sensors performance will be changed badly if sensors be sprayed polluted by alkali metals salt
especially brine, or be exposed to halogen such as fluorine.
1.4 Touch water
Sensitivity of the sensors will be reduced when spattered or dipped in water.
1.5 Freezing
Do avoid icing on sensor’s surface, otherwise sensing material will be broken and lost sensitivity.
1.6 Applied higher voltage
Applied voltage on sensor should not be higher than stipulated value, even if the sensor is not
physically damaged or broken, it causes down-line or heater damaged, and bring on sensors’
sensitivity characteristic changed badly.
1.7 Voltage on wrong pins
For 6 pins sensor, Pin 2&5 is heating electrodes, Pin (1,3)/(4,6) are testing
electrodes (Pin 1 connects with Pin 3, while Pin 4 connects with Pin 6).If
apply voltage on Pin 1&3 or 4&6, it will make lead broken; and no signal
putout if apply on pins 2&4.
Fig8. Lead sketch
2 .Following conditions must be avoided
2.1 Water Condensation
Indoor conditions, slight water condensation will influence sensors’ performance lightly. However, if
water condensation on sensors surface and keep a certain period, sensors’ sensitive will be decreased.
2.2 Used in high gas concentration
No matter the sensor is electrified or not, if it is placed in high gas concentration for long time, sensors
characteristic will be affected. If lighter gas sprays the sensor, it will cause extremely damage.
2.3 Long time storage
The sensors resistance will drift reversibly if it’s stored for long time without electrify, this drift is
related with storage conditions. Sensors should be stored in airproof bag without volatile silicon
compound. For the sensors with long time storage but no electrify, they need long galvanical aging
time for stability before using. The suggested aging time as follow:
Stable2.
Storage Time
Suggested aging time
Less than one month
No less than 48 hours
1 ~ 6 months
No less than 72 hours
More than six months
No less than 168 hours
2.4 Long time exposed to adverse environment
No matter the sensors electrified or not, if exposed to adverse environment for long time, such as high
humidity, high temperature, or high pollution etc., it will influence the sensors’ performance badly.
2.5 Vibration
Continual vibration will result in sensors down-lead response then break. In transportation or
assembling line, pneumatic screwdriver/ultrasonic welding machine can lead this vibration.
2.6 Concussion