MQ-2 Semiconductor Sensor for Flammable Gas 

 

 

Profile 

Sensitive material of MQ-2 gas sensor is SnO

2, 

which 

with lower conductivity in clean air. When the target 
flammable gas exist, the sensor’s conductivity gets 
higher along with the gas concentration rising. Users 
can convert the change of conductivity to correspond 
output signal of gas concentration through a simple 
circuit. 
MQ-2 gas sensor has high sensitivity to propane and 
smoke, also can detect the natural gas and other 
flammable steam well. It is with low cost and suitable 
for different applications of detecting kinds of 
flammable gases.

                                                          

 

Features 

It has good sensitivity to propane, smoke &etc in wide range, and has  advantages such as long lifespan, 
low cost and simple drive circuit &etc.                                                                                                                                       

Main Applications 

It is widely used in domestic gas leakage alarm, industrial flammable gas alarm    and portable gas 
detector. 

Technical Parameters                Stable.1 

Model 

MQ-2 

Sensor Type 

Semiconductor 

Standard Encapsulation 

Bakelite, Metal cap 

Target Gas 

Flammable gas, smoke 

Detection range 

300

10000ppm(flammable gas) 

Standard Circuit 

Conditions 

Loop Voltage 

V

c

 

≤24V DC 

Heater Voltage

 

V

5.0V±0.1V AC or DC 

Load Resistance

 

R

Adjustable 

Sensor character 

under standard 

test conditions 

Heater Resistance

 

R

29Ω±3Ω

room tem.

 

Heater consumption

 

P

≤950mW 

Sensitivity 

Ro(in air)/Rs(2000ppm C

3

H

8

)≥5 

Output Voltage   

Vs 

2.5V

4.0V

in 2000ppmC

3

H

8

 

Concentration Slope 

α 

≤0.6(R

3000ppm

/R

1000ppm 

C

3

H

8

Standard test 

conditions

 

Tem.    Humidity 

20

±2

℃;

55%±5%RH 

Standard test circuit 

Vc:5.0V±0.1V

 

V

H

:5.0V±0.1V 

Preheat time 

Over 48 hours 

Fig1.Sensor S

tructure 

Unit: mm

 

Reviews: