SECTION 6 –
ELECTRICAL
6-4
When the inverter is not being used, it should
be shut off at the control panel. The inverter
could drain the house batteries if the shoreline is
not connected to external power and the House/
Coach Battery Disconnect switch is on.
Further Information
See the inverter control panel instructions in
your InfoCase for complete instructions and
charging setup directions.
POWER CENTER
Converter
The power converter is generally located in a
lower cabinet face in the galley or living area
depending on the floorplan of your model.
The converter power panel contains the house
electrical system 120-volt circuit breakers and
12-volt breakers or fuses.
The power converter changes 120-volt AC
current from the auxiliary generator or the
shoreline into 12-volt DC current for use by 12-
volt equipment in the motorhome.
Certain circuits, however, remain unchanged
for use by items which require 120-volt current,
such as the air conditioner(s), the refrigerator in
AC mode, the microwave oven, etc.
NOTE: The converter will not change 12-volt
DC current to 120-volt AC.
Current drawn from the house batteries passes
through the power converter unchanged,
although it is routed through a series of protective
fuses located on the power panel.
Further Information
See the manufacturer’s operation, care and
maintenance information in your InfoCase.
Charging Section
The converter charges house batteries while
120-volt external power is connected. The
converter will automatically “sense” the
condition of the battery. If it is below “full
charge”, the Charging Section will start charging
the batteries.
If the house batteries have been extremely
discharged, they will accept charge at a relatively
high amperage rate. If they are only slightly
discharged, they will charge at a lower amperage
rate. The rate of charge will decrease as the
batteries reach “full charge”, then will continue
“trickle” charging at a very low amperage rate. If
your battery does not charge as described above,
it is possible the battery is defective.
Thermal Overload
A thermal overload will “break” the 120-volt
AC power to the converter section of the Power
Center if the power converter becomes
overheated. This can result from operating above
its maximum limit for an extended period of time
or by obstruction of ventilation to unit.
NOTE: The power converter section will
automatically route 12-volt lights and
motors to house battery power in this
event.
12-Volt House
Circuit Breakers
120-Volt House
Circuit Breakers
Power Center
-Typical View
NOTICE
Do not block the converter cover vents in
any way. The converter generates heat
while operating and needs unrestricted
airflow for proper cooling. Damage to the
converter can result.