Appendix
Appendix D: Military Grade Compliance
This section includes description of military grade compliance.
Military Grade EMC Compliance
EMC (MIL-STD 461E/F Compliance)
EMC Test Spec
Type of Test
Frequency Range
Requirement
CE101
Conducted Emissions
30Hz ~10kHz
30Hz ~ 1kHz :110 dB 1k-
10k:110-90 dB
CE102
Conducted Emissions
30Hz ~10kHz
10kHz ~ 500KHz: 100-66dB,
500KHz~10MHz:66dB
RE101
Radiated Emissions
30Hz ~100kHz
30~100k :180-110 dBpT
RE102
Radiated Emissions
10kHz ~-18GHz
2MHz~18G Hz: 44-89 dB
Military Grade Environmental Compliance
Environmental (MIL-STD 810F/G Compliance)
High Temperature
Operating
30°C to 60°C, Method 501.5 / Procedure II
Storage
30°C to 60°C, Method 501.5 / Procedure I
Low Temperature
Operating
-
33°C, Method 502.5 / Procedure II
Storage
-
33°C, Method 502.5 / Procedure I
Thermal Shock
-
33°C to 63°C, Method 503.5 / Procedure I-B
Humidity
30°C to 60°C, 95 ± 2% RH, Method 507.5
Low Pressure
Operating
15,000 ft, Method 500.5 / Procedure II
Storage
15,000 ft, Method 500.5 / Procedure I
Salt Fog
Method 509.5
Vibration
5 ~ 500 Hz, 1.48 & 1.90 & 2.24 Grms
Method 514.6 / Procedure I
Transit Drop
Method 516.6 / Procedure IV
Shock
Method 516.6 / Procedure I