2.4 Safety when using cylinders in low temperatures
Reduced power of the batteries
Warning
Malfunctions in the locking process due to reduced
power of the batteries at low temperatures!
At temperatures under 5°°C, the power of the
installed batteries can reduce significantly even
without a cylinder locking operation. In this case,
it may no longer be possible to operate the
cylinder with a passive key. Doors which do not
function correctly may result in death in hazardous
situations.
•
For locking operations outdoors and/or at low
temperatures, use an active key to use the
internal power function.
–
see "Use internal power function", page 15
•
Ensure that all users operating the locking
system outdoors and/or at low temperatures
are equipped with an active key and relevant
locking rights.
–
see "Add and manage key", page 64
•
Instruct users that active keys may only be
deposited at temperatures over 5°°C.
2.5 Instructions on integrating alarm systems
Malfunctions in alarm systems
Note
Malfunctions in alarm systems when the locking
system is integrated incorrectly!
If the locking system is incorporated into the higher
level alarm system incorrectly, the alarm system
may malfunction.
•
Only specialist companies may incorporate the
locking system into the alarm system.
2.6 The administrator's responsibilities
The locking system administrator manages the Masterkey and the PUK
and activation cards. The administrator is responsible for issuing locking
rights.
blueCompact electronic locking system
27