CHARACTERISTICS 

The DirectXion lock can be mounted in all four mounting directions.  Also, by flipping the lock, 
all blocking directions can be achieved. The mounting dimensions are standard.  The lock is 
delivered with metric (M6) mounting screws. The PCB board in this lock is intended as an 
OEM solution for customers who would like to control the lock via their own electronics. Once 
voltage is supplied the lock will open for a 5 seconds and the boltwork can be moved into 
OPEN position by pushing the bolt inside the lock case. After 5 seconds the board will cut 
power to blocking element regardless if voltage is still supplied from external system. When 
moving the boltwork into LOCKED position the DirectXion automatically locks. To open the 
lock again the voltage has to be dropped and re-applied. 

BOLTWORK REQUIREMENTS and MOUNTING INSTRUCTIONS 

The maximum allowed cable/spindle-hole diameter is 12mm (if located under the lock body) 

If the DirectXion lock is used in conjunction with another lock, the boltwork must be 
constructed in a way that the DirectXion secures first. 

In the LOCKED position the distance between the 
DirectXion bolt and the boltwork part that is 
moving the lock bolt should be approximately 1 
mm.  

Only use supplied screws to mount the lock. 
Tighten the screws securely so the lock body is 
attached firmly to the mounting surface. 