background image

CONTROL PANEL

1. Power ON/OFF

Pressing 

button (1)

 will turn the machine on.  

Pushing again will turn the machine off.  

Please note unit may run on and off depending 

on humidity levels and programmed humidity set.

2. Select Operating Mode

* Auto Mode

When the unit is turned on for the first time or by 

cycling through the settings using the 

setting button 

(3)

 until 

auto indicator

 

(9)

 is lit, operation begins 

in auto mode. "50" will appear in the 

display (5)

 

and the auto indicator 

(9)

 will light up. In this setting, 

humidity level and fan speed is adjusted for optimum 

comfort (50%) with no manual adjustment needed. 

If a 

humidity adjustment arrow (15)

 or 

fan speed 

button

 

(2)

 is pressed while in auto mode, the unit

will switch to humidity mode automatically.

* Humidity Mode

To set desired humidity level when not in auto mode,

push 

setting button (3)

 until 

humidity indicator 

(10) 

is lit. The humidity levels will adjust in increments

of 5% beginning at a low of 35% and reaching a 

maximum of 70%. Humidity will show in the display 

when adjusting humidity level. To adjust humidity

level up or down, press 

humidity adjustment 

arrows (15)

 until desired humidity level is reached.

* Cycle Run Time

To set Cycle Run Time, push 

setting button (3) 

until

 cycle run time indicator (11)

 is lit. In this 

setting, the unit will run for either 3, 6, or 12 hours,

then shut off for 3, 6, or 12 hours, then turn on 

5. Low Room Humidity Indicator

Low room humidity indicator (7)

 will light when 

unit detects low humidity levels.

 

 

 

 

 

 

   

 

 

 

 

   

 

 

 

 

  

 

3.

 

Select Your Fan Speed 

By pressing 

fan speed

 button

 (2)

, fan speed will 

change. The 

indicator (8)

 of selected fan speed 

will light (High or Low). In Auto Mode, fan speed 

will adjust the fan speed automatically depending

how close the room humidity is to 50%. For example, 

if the room is 70%, the unit will need to pull in air 

quickly, so it will turn on high. Once the room 

reaches 55%, the unit will slow the amount of air 

flow and turn the fan on low.  Fan Speed can be 

adjusted in all settings except for auto mode.

* Continuous Mode

To set the unit into continuous mode, push 

setting 

button (3)

 until 

continuous indicator (12)

 is lit. 

Continuous mode will run the compressor and fan 

continuously until it is powered off or until another 

setting is inputted. When continuous mode is 

programmed, “Co” will be displayed.  Fan speed

can be adjusted in this mode.

4. Water Removal Indicators

* Pump ON

Pump setting button is selected when using the 

automatic pump feature with included 18 ft. hose

To select the pump as your water removal option, 

press the 

pump button (4)

. When the 

pump 

indicator (13)

 is on, the pump will automatically 

remove the water in the bucket only when the 

bucket is full. The pump light must be on at all time 

to use this function. It will only turn on for a period 

of 30 seconds to remove the water. The pump will

turn off after 30 seconds and not turn on again until 

the bucket is full again. It is normal for a small 

amount of water to remain in the bucket after the 

pump has operated; this is to protect the pump. 

The pump button should be off at all times except 

when the user chooses this as their option to remove 

collected water (See Page 7, Option 3).  The pump 

option should only be selected when there is a ¼”

hose properly installed in the pump drain location.  

If the pump button is pressed when using other 

disposal options, E3 (Error message – See page 10) 

will be displayed. If other disposal options are 

needed, push the pump button again to turn off the

pump function.

* Bucket Full Indicator

When the collection bucket is full, 

bucket full 

indicator (6)

 will light. The unit will not run with the

bucket full. Dispose of water and replace bucket 

properly.

 

 

 

 

 

 

 

 

 

  

     

 

 

   

     

 

 

 

   

  

 

   

 

   

 

   

1

7
8

6

14

15

3

11

4

9

10

13

5

2

12

again in the same cycle. To program Cycle Run 

Time, the 

cycle run time indicator (11)

 must be 

lit. Cycle Run Time can be adjusted by pushing the 

timer adjustment arrows (14)

 up or down to set

operating time for 3, 6, or 12 hours. The cycle timer 

function will continue until you change the setting

or turn the unit power off. In this setting, the unit 

will operate on the last humidity setting programmed.  

During cycle run time operation, compressor and 

fan may shut off depending on programmed 

humidity level.

NOTE:  THIS UNIT IS EQUIPPED WITH A POWER 

FAILURE AUTO RESTART. IN THE EVENT OF 

A POWER FAILURE THIS UNIT WILL TURN 

BACK ON TO ITS LAST SETTING ONCE POWER 

IS RESTORED.

Dehumidifier pint capacity is defined as how

much moisture it can draw out of the air in a

24 hour period in 80 degrees F and 60% 

Relative Humidity. Once humidity begins to 

drop from 60%, the amount of moisture in 

the air begins to fall, which will result in less

water in your bucket. 

www.sylvane.com  1-800-934-9194

Summary of Contents for WDH 851

Page 1: ... information on Winix products NOTE IF YOU EXPERIENCE A PROBLEM PLEASE CONTACT CUSTOMER SERVICE RE FER TO YOUR WARRANTY DEFECTIVE UNITS SHOULD BE RETURNED TO THE PLACE WHERE ORIGINALLY PURCHASED DO NOT ATTEMPT TO REPAIR THE APPLIANCE YOURSELF DOING SO WILL VOID YOUR WARRANTY AND MAY RESULT IN GREATER DAMAGE TO THE DEHUMIDIFIER OR PERSONAL INJURY www sylvane com 1 800 934 9194 ...

Page 2: ...y slow down resulting in less accumulation of water Do not put a pet or house plant where it will be exposed to direct air flow This could injure the pet or plant Do not use the water collected in the bucket for drinking purposes It is not sanitary and could cause illness Operation without filter will cause unit failure Insert the filter securely Clean it every two weeks See maintenance Do not allow ...

Page 3: ...prong electrical outlet A time delay fuse or time delay circuit breaker is recommended Use a dedicated circuit serving only this appliance CONTROL PANEL FRONT GRILL CASTER HANDLE GRAVITY DRAIN PUMP DRAIN BUCKET AIR INLET FILTER 18 ft PUMP DRAIN HOSE GRAVITY HOSE ATTACHMENT CHOOSING THE PROPER LOCATION Place the dehumidifier on a level floor strong enough to support the unit with a full bucket of w...

Page 4: ... continuous mode is programmed Co will be displayed Fan speed can be adjusted in this mode 4 Water Removal Indicators Pump ON Pump setting button is selected when using the automatic pump feature with included 18 ft hose To select the pump as your water removal option press the pump button 4 When the pump indicator 13 is on the pump will automatically remove the water in the bucket only when the b...

Page 5: ...e the drain hole GREY RUBBER PLUG by pulling out while pressing in on the coupler Fig 2 Keep the DRAIN CAP and PLUG for future use 3 Feed the 1 4 inch hose provided through the hole in the DRAIN CAP Fig 3 4 Insert the end of hose into the drain hole Fig 4 then screw DRAIN CAP back onto the unit Place the other end of the hose in the location you want the water to go to a floor drain a water contain...

Page 6: ... can solve your problem without outside help PROBLEMS CHECK POINT SOLUTIONS Dehumidifier does not work when pressing the POWER ON button Is the power cord plugged into a grounded 3 prong outlet Is BUCKET FULL light on Does BUCKET FULL light appear after emptying the water bucket Plug the power cord securely into a grounded 3 prong outlet Empty the water bucket and re install Check the float switch t...

Reviews: