background image

18

English

                               

50BT, 70BT

WINIX DEHUMIDIFIERS LIMITED WARRANTY

Limited Warranty: Winix warrants the parts of the machine to be free of defects in material and 

workmanship and provides service and support for one (1) year from the date of purchase by the 

original consumer for models 50BT and 70BT.

If any part is found to be defective during the warranty period, your sole and exclusive remedy 

will be repair or replacement, at Winix's option and expense, of the defective part.

This warranty does not apply in cases of abuse, mishandling, failure to comply with product 

usage standards, operation using an improper power supply (other than listed on the label), or 

unauthorized repair.

Winix reserves the right to charge the consumers for any additional costs incurred by Winix to 

provide parts or services outside of the country where the air purifier is initially sold by an 

authorized reseller. This warranty does not include the air cleaner's replaceable filters, which are 

expendable parts that wear out from normal use.

ANY IMPLIED WARRANTY, INCLUDING THAT OF MERCHANTABILITY OR FITNESS FOR A 

PARTICULAR PURPOSE, IS HEREBY LIMITED IN DURATION TO THE APPROPRIATE WARRANTY 

PERIOD SET FORTH ABOVE.

In no event shall Winix be liable for any consequential or incidental damages attributable to this 

product.

This warranty gives you specific legal rights. The duration , terms and conditions of this warranty 

are valid worldwide, except where different limitations, restrictions, or conditions may be 

required by local law.

For more details or to obtain service under this warranty, please contact your local dealer.

Summary of Contents for 50BT

Page 1: ...llow all safety rules and instructions in this manual before operating x The product warranty is printed on the back of this guide so please keep it in a safe place for future use x This product is ma...

Page 2: ...FOR THE HOME...

Page 3: ...FOR THE FAMILY...

Page 4: ...afety Instructions Safety and Cautions 8 Operation Bucket 9 Gravity Drain 10 Care and Maintenance Grill and Filter 11 Exterior 12 Bucket 13 Troubleshooting Frequently Asked Questions 14 Unit Specifica...

Page 5: ...ronment between 35 to 70 in increments of 5 Shows information when setting Cycle Timer or Delay Start I Auto When the unit is initially powered on it will run in AUTO mode The unit will automatically...

Page 6: ...70BT Control Panel Air Intake Vents Water Level Window Water Bucket Molded Hand Grips Air Outlet Vents Gravity Drain Connector Casters Power Plug UNIT Always keep unit in upright position Do not allo...

Page 7: ...ve unit facing into wind or draft Only place on hard flat surfaces that is secure enough to hold over 70 lbs Allow 12 18 in of space between TVs radios and other electronic products electromagnetic in...

Page 8: ...t unplug or move the unit while in operation If the unit becomes submerged in water unplug it and contact customer service Cord can become damaged by forcefully bending pulling twisting bundling pinch...

Page 9: ...in ideally a sink After the bucket is emptied the bucket will need to be replaced by sliding the bucket back into the unit 2 Gravity Drain Hose This method will allow a hose to be connected to the rea...

Page 10: ...rol that senses frost buildup on the evaporator coils x During defrosting the compressor will automatically turn off the fan will continue running to defrost the coils Automatic Shut off x When the bu...

Page 11: ...l Remove the bucket from the unit the air filter is located behind the front grill Pull the filter down and away from the unit until it is all the way out Wash the filter with water rinse thoroughly A...

Page 12: ...Cleaning the Exterior Clean the exterior using a soft brush or dry towel But do not spray water directly on the unit The Front Grill can be cleaned using a vacuum cleaner or a soft brush to remove dus...

Page 13: ...the unit lift off the cover Clean the inside and outside of the bucket as needed Rinse the bucket and drain Replace the bucket Ensure float switch is not obstructed Proper position of the bucket and...

Page 14: ...er Is the compressor running as well as the fan The unit may be in the defrost mode This is noted by the fan running but not the compressor If this is the case regular operation will begin to run auto...

Page 15: ...difier is not running efficiently Are the grill and filter dirty Clean the Front Grill and Air Filter see p 12 Is the indoor temperature under 65o F If yes frost can develop easily which will inhibit...

Page 16: ...ment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions and may cause harmful interference to radio communications However there is...

Page 17: ...use the fan rotates at high speed during operation always unplug dehumidifier before attempting any recommended maintenance or cleaning x Do not block the inlet or outlet vents It may cause unit to fa...

Page 18: ...to charge the consumers for any additional costs incurred by Winix to provide parts or services outside of the country where the air purifier is initially sold by an authorized reseller This warranty...

Page 19: ......

Page 20: ...fy the model name and number the nature of the problem your contact information and your address 151216 Rev 2 1 1 x Dedicated Call Center 877 699 4649 xWebsite www winixamerica com x Contact your loca...