15 

 

4.3 

FLEXIBLES INTALLATION ON OUTSIDE UNIT 

 
 

 

 

• Put the hoses in place 

• BE CAREFUL TO RESPECT THE COLOR CODE ON YOUR MACHINE (blue linked to r blue, 
red linked to red) (2)

 

 

 

CONNECTION AND INSTALLATION OF THE PRO VERSION 

 

5.1 

FLEXIBLES 

 

The connections must be made of copper for refrigeration use of diameter 

3/8’’ 

The 2 connections have the same diameter. 
Do not exceed a length of 15 meters 

 

RED 

BLUE 

Summary of Contents for WineSP100

Page 1: ...UIDE Please keep INDICATIONS PLACED ON THE NAMEPLATE FOUND ON THE APPLIANCE Model Serial number Purchase date IMPORTANT IT IS RECOMMENDED TO NOTE THE SERIAL NUMBER AND TO WRITE IT DOWN IN THE BOX ABOV...

Page 2: ...N OF THE WALL MOUNTING BRACKETS 11 2 4 2 ATTACHING THE OUTSIDE UNIT 11 3 INSTALLATION OF THE INSIDE UNIT 13 3 1 RE CONNECTION OF THE FLEXIBLE 13 3 2 INSTALLING THE CONDENSING WATER FLUE 13 4 FLEXIBLE...

Page 3: ...3 8 WARRANTY 22 8 1 YEARS CONTRACTUAL WARRANTY 22 8 2 TERMS OF APPLICATION OF THE GUARANTEE 22 8 3 EXCLUSIONS AND LIMITS OF GUARANTEE 22...

Page 4: ...eat storage and best wines aging for an incomparable pleasure Because the customer is at the heart of all our thoughts we want to support you in your first steps and lead you towards the best use of y...

Page 5: ...le connection 4 50 m or 8 m The circuit breaker must be at least 16 Amps The insulation quality and thickness has to be in accordance with the volume of the cellar and the set temperature The cooling...

Page 6: ...ssential for the Winemaster to work properly Adequate insulation helps to obtain the stability of the temperature and the humidity The board on the next page choice of insulation can be used to determ...

Page 7: ...insulation glasswool stonewool because it stores humidity and loose its insulation capacity Protection against rodents Some insulating materials are damaged by rodents mice rats It is therefore essent...

Page 8: ...e insulated 2 INSTALLING THE OUTSIDE UNIT Before any intervention with interior of the unit the electric cable must be disconnected Make sure you have chosen the best place for fitting the outside uni...

Page 9: ...9 2 3 FLEXIBLE DISMOUNTING 2 3 1 THE COVER 2 1 Unscrew the two black platic screws 1 Open the cover like shown on the picture 2...

Page 10: ...Unscrew the 5 screws 1 with a screwdriver PZ2 for unmounting the brackets 2 et 3 2 3 3 THE REFRIGERANT CONNECTION 2 1 3 Two wrenches 1 2 are supplied with the unit Maintain the connection with the wre...

Page 11: ...ection in order to avoid dust goes out 2 3 4 ELECTRICAL CONNECTOR The ventilator of the outside unit is connected by an electric cable Disconnect the connector 3 2 4 INSTALLATION OF THE OUTSIDE UNIT 2...

Page 12: ...12 1 2 Position the outside unit so that the screws and washers 1 are engaged in the slot 2 1 To finish screw the kit screws and washer 1 under the unit...

Page 13: ...with the wrenches and the electrical connecting wires to the outside unit The reconnection can be done to any pipe Attention open the ends of the flexible connection when you pass them through the wa...

Page 14: ...AND 8M VERSION 4 1 THE COVER 2 1 Unscrew the two black plastic screws 1 Lift cover 2 by rotating it as shown in the drawing 4 2 THE FIXING BRACKETS Unscrew the 5 screws 1 using a screwdriver PZ2 to re...

Page 15: ...COLOR CODE ON YOUR MACHINE blue linked to r blue red linked to red 2 5 CONNECTION AND INSTALLATION OF THE PRO VERSION 5 1 FLEXIBLES The connections must be made of copper for refrigeration use of diam...

Page 16: ...OVER 2 1 Unscrew the two black plastic screws 1 Lift cover 2 by rotating it as shown in the drawing 5 3 THE FIXING BRACKETS Unscrew the 5 screws 1 using a screwdriver PZ2 to release the retaining flan...

Page 17: ...CONNECTION ON INSIDE UNIT Solder the copper connections to the fittings CAUTION RESPECT THE COLOR CODE ON YOUR MACHINE blue linked to blue red linked to red 5 5 REFRIGERATION CONNECTION ON OUTSIDE UNI...

Page 18: ...he Winemaster SP100 must be installed by complying with the national rules of electric installation 6 1 CONNECTING THE AIR CONDITIONER Connect the male plug to a 230 16A power socket Switch on the air...

Page 19: ...ged compressor working Red light Not used Red light and or dF defrost Red light heat mode engaged resistance IA code external alarm or open door depending model dEF code manual defrost engaged see 5 5...

Page 20: ...emperature 6 5 MANUAL DEFROST 7 SERVICING THE WINEMASTER AIR CONDITIONER THE DUST FILTER It is essential to replace the dust filter in the air conditioner as soon as necessary and at least once a year...

Page 21: ...be due to several causes obstruction filter clogged breakdown of outside fan unit local where is the outside unit badly ventilated In the case 1 and 2 the simple rearmament of the device having delete...

Page 22: ...ation and operating guide His application is conditionned by the presentation of the invoice of purshace or for lack of its copy 8 3 EXCLUSIONS AND LIMITS OF GUARANTEE The guarantee is refused in the...

Reviews: