Installation 

For questions or help regarding installation, call customer service at 1-315-452-7400 or 
email 

[email protected]

 a sketch of the proposed area where the unit is to be 

installed.

 

Pre-Installation 

 

HUMIDIFIER MAY NOT BE INSTALLED WHERE IT MIGHT BE EXPOSED TO 

FREEZING TEMPERATURES. IF THE COOLING UNIT IS MOUNTED OUTSIDE, THE 

HUMIDIFIER WILL HAVE TO BE MOUNTED IN THE SUPPLY DUCT TO THE 

CELLAR INSIDE THE BUILDING OR MOUNTED AS A FREESTANDING UNIT 

INSIDE THE CELLAR. 

To check for any possible non-visible shipping damage, you may wish to test the unit 
before installing it. To do so, remove the unit from its packaging and set it on any sturdy 
level surface. If your humidifier is a freestanding unit, plug in the unit. If the unit is to be 
connected to a cooling unit, you need to wire the humidifier to the cooling unit and the 
cooling unit must be turned on (Refer to page 14). Set the humidistat above the room 
humidity. The unit should now come on. The water solenoid should open, and the fan 
should come on. Listen for any unusual noise or vibration. Change the humidistat

’s set 

point below the room

’s current condition and the unit should turn off.

 

 

NEVER MODIFY THIS EQUIPMENT. CHANGES OR MODIFICATIONS MAY VOID 

THE WARRANTY, CAUSE DAMAGE TO THE EQUIPMENT, AND/OR CREATE A 

SAFETY HAZARD.

 

NEVER PLACE ANYTHING ON TOP OF THE UNIT. NEVER BLOCK OR COVER 

ANY OF THE OPENINGS OR OUTLETS OF THE UNIT.

 

NEVER ALLOW ANYTHING TO REST ON OR ROLL OVER THE POWER CORD, 

AND NEVER PLACE THE UNIT WHERE THE POWER CORD IS SUBJECT TO 

WEAR OR ABUSE.

 

DO NOT REMOVE OR OPEN ANY ACCESS DOOR OR COVER UNLESS THE UNIT 

IS UNPLUGGED. 

 

 

 

 

 

 

 

Summary of Contents for 99H0173-20

Page 1: ...m airinnovations com Wine Guardian reserves the right without notice to make changes to this document at its sole discretion Please visit our web site for the most current version of the Wine Guardian...

Page 2: ...ram Freestanding Humidifier 50Hz 11 Humidifier Dimensions Freestanding 12 Humidifier Dimensions Integrated 13 Installation 14 Pre Installation 14 Freestanding Installation 15 Integrated Installation S...

Page 3: ...ion between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician...

Page 4: ...Installation and maintenance of this equipment is to be performed only by qualified personnel who are familiar with local codes and regulations and are experienced with this type of equipment Exposur...

Page 5: ...ving Inspecting and Unpacking When receiving the unit ensure the unit is undamaged and includes all ordered accessories Note Wine Guardian units are factory assembled and tested prior to shipment Wine...

Page 6: ...ine Guardian system Integrated humidifier that mounts directly to the side of any ducted or split Wine Guardian system Humidifier is controlled by the Remote Interface Controller via communication cab...

Page 7: ...ir in the air at a given air condition Moisture water that has been evaporated into the air NEC National Electrical Code Set point the desired temperature or humidity that is set on the Thermostat or...

Page 8: ...er does it contribute to more humidification The drain volume is too much for just a bucket A gravity drain line should be piped to an open floor or sink drain or a condensate pump may be used where a...

Page 9: ...9 Wiring Diagram Integrated Humidifier 60Hz 50Hz...

Page 10: ...10 Wiring Diagram Freestanding Humidifier 60Hz...

Page 11: ...11 Wiring Diagram Freestanding Humidifier 50Hz...

Page 12: ...12 Humidifier Dimensions Freestanding...

Page 13: ...13 Humidifier Dimensions Integrated...

Page 14: ...ing unit plug in the unit If the unit is to be connected to a cooling unit you need to wire the humidifier to the cooling unit and the cooling unit must be turned on Refer to page 14 Set the humidista...

Page 15: ...onnection at the top of the humidifier see Fig 7 on page 14 A shut off valve not provided is recommended to isolate the humidifier from the water system when needed 5 Install a 1 2cm flexible drain li...

Page 16: ...16 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Fig 8...

Page 17: ...captive latches to secure the access panel to the humidifier housing See Fig 9 on this page 3 Remove side access panel on the side of the cooling unit where you wish to mount the humidifier 4 Install...

Page 18: ...seen on the next page to the Wine Guardian unit with the 4 8 32x1 25 screws provided 4 Hook the cleat at bottom of the humidifier over the bottom edge of the opening on the adaptor plate 5 Rotate the...

Page 19: ...19 Fig 11...

Page 20: ...en on the next page to the Wine Guardian unit with the screws that were removed from the door 4 Hook the cleat at bottom of the humidifier over the bottom edge of the opening on the adaptor plate 5 Ro...

Page 21: ...21 Fig 12 Fig 13...

Page 22: ...22 Fig 14 Fig 15...

Page 23: ...button and hold it down for five 5 seconds The screen will advance to the set up menu and 1 F will appear on the screen see pictorial on page 23 For 50Hz models default will be 1 C 3 Continue to pres...

Page 24: ...24...

Page 25: ...CONTAINED IN THE BOX WITH THE HUMIDISTAT WE RECOMMEND YOU FOLLOW WINE GUARDIAN S HUMIDISTAT INSTRUCTIONS AND SIMPLY RETAIN THE HUMIDISTAT MANUFACTURER S INSTRUCTIONS IN A FOLDER ALONG WITH THE WINE G...

Page 26: ...ir The drain system may also trap dust and dirt When water no longer stays on the pad or mineral build up has started to reduce airflow the pad needs to be replaced Suggested Maintenance Schedule Mont...

Page 27: ...its are present install a new evaporative pad Replace the pad by lifting up on the spring loaded drip tray Note the pad must be installed in the correct position There is a black spot painted on one e...

Page 28: ...tall the strainer in the valve inlet replace the tubing and tighten the compression nut Double wrench to prevent damage and leaks 7 Disconnect the water line on the outlet of the solenoid valve 8 Remo...