![Wine Corner WINE SP100 User Manual Download Page 7](http://html1.mh-extra.com/html/wine-corner/wine-sp100/wine-sp100_user-manual_985985007.webp)
7
2.3.5 THE
DOOR
It is part of the continuity of insulation.
There are two possible solutions :
-
to insulate the existing door using the same type as insulation as was used for the cellar walls. Insert a
seal such a foam, between the door panel and the frame all around the edge.
-
Use a FONDIS isothermal door, lined with polyurethane foam. It includes a seal around its periphery,
with a magnetic closure..
2.3.6 INSULATION OF OTHER ITEMS
A fridge or another appliance producing heat must not be placed inside the cellar. For example, any hot water
pipe going through the cellar must also be insulated.
3
INSTALLING THE OUTSIDE UNIT
Make sure you have chosen the best place for fitting the outside unit :
- Chose the best place in order that the length of the flexible connection will be shorter as
possible.
- There should not be any obstacle in front of the ventilation grid and the back of the unit, to
facilitate air flow
- The wall structure should be strong enough to carry the unit weight and avoid deformations
rupture, or vibration during operation
3.1
DRILLING THE WALL
Drill one hole of diametre 70mm to allow the connection of the flexible refrigerant tube to the unit.
3.2
FLEXIBLE DISMOUNTING
3.2.1 THE
COVER
2
1
•
Unscrew the two black platic screws
1
.
•
Open the cover like shown on the picture
2
.