LAYOUT OF PREMISES
The air-conditioner is composed by two separate units which are connected by an electric and refrigerant flexible
cable of 5 mts. The distance between the two units cannot be more than 5 mts.
2.1 INDOOR
UNIT
The indoor unit is entirely installad inside the cellar directly on the floor or fixed on the wall with adapted special
brackets.
2.2 OUTSIDE
UNIT
The outside unit must be fixed on an outside wall in an area free from obstruction which may cause irregular air
distribution and/or return in front and back of the unit.
2.3 THE
CELLAR
2.3.1 INSULATION
Insulation of the 4 walls, the door, the ceiling and the floor is essential for the Winemaster to work properly.
Adequate insulation helps to obtain the stability of the temperature and the humidity.
The board on the next page ( choice of insulation ) can be used to determine the type and the thickness of
insulation needed according to the internal volume of the cellar and a cellar temperature of 12
°
C.
Insulation continuity :
Insulation components must be assembled preferably by interlocking panels or glueing the panels together, to
ensure perfect continuity of insulation.
This is very important : it prevents heat and humidity entering from the outside which would counter the effects
of regulation.
IMPORTANT
The validity of the
WINEMASTER guarantee depends on the values in the
"Choice of insulation"
table being strictly respected, for all the cellar walls, including floor and c door, as well as
perfect continuity of insulation and installation in accordance to the user guide.