background image

D

E

F

Y

I

N

G

 

C

O

N

V

E

N

T

I

O

N

W I N E   S P 10 0

U S E R   G U I D E

Summary of Contents for WINE SP100

Page 1: ...D E F Y I N G C O N V E N T I O N WINE SP100 U S E R G U I D E...

Page 2: ...BRACKETS 8 3 2 3 THE REFRIGERANT CONNECTIONS 8 3 2 4 ELECTRICAL CONNECTOR 9 3 3 INSTALLATION OF THE OUTSIDE UNIT 9 3 3 1 INSTALLATION OF THE WALL MOUNTING BRACKETS 9 3 3 2 ATTACHING THE OUTSIDE UNIT 9...

Page 3: ...wine If you follow our advice and respect our recommendations Winemaster will provide the optimal ageing conditions for your treasured wine collection You have to read the installation and operating g...

Page 4: ...insulation quality and thickness has to be in accordance with the volume of the cellar and the set temperature The cooling performance is dependant from the outside temperature Therefore the set tempe...

Page 5: ...k properly Adequate insulation helps to obtain the stability of the temperature and the humidity The board on the next page choice of insulation can be used to determine the type and the thickness of...

Page 6: ...panel facing is important it protects the insulation from shocks and guarantees long life Do not use mineral fibre insulation glasswool stonewool because it stores humidity and loose its insulation ca...

Page 7: ...going through the cellar must also be insulated 3 INSTALLING THE OUTSIDE UNIT Make sure you have chosen the best place for fitting the outside unit Chose the best place in order that the length of the...

Page 8: ...nscrew the 5 screws 1 with a screwdriver PZ2 for unmounting the brackets 2 et 3 3 2 3 THE REFRIGERANT CONNECTIONS 2 1 3 Two wrenches 1 2 are supplied with the unit Maintain the connection with the wre...

Page 9: ...ction in order to avoid dust goes out 3 2 4 ELECTRICAL CONNECTOR The ventilator of the outside unit is connected by an electric cable Disconnect the connector 3 3 3 INSTALLATION OF THE OUTSIDE UNIT 3...

Page 10: ...10 1 2 Position the outside unit so that the screws and washers 1 are engaged in the slot 2 1 To finish screw the kit screws and washer 1 under the unit...

Page 11: ...refrigerant fittings with the wrenches and the electrical connecting wires to the outside unit The reconnection can be done to any pipe Attention open the ends of the flexible connection when you pas...

Page 12: ...ne seconde until the message o1 appears Press then the button 3 the set temperature of the cellar will appear Use again the button 1 to increase the temperature or the button 2 to lower the temperatur...

Page 13: ...13 6 1 CHANGING THE FILTER 2 1 3 Unscrew the two plastic screws 1 Remove the cover 2 Pull the tab 3 to release the filter Replace it with a FONDIS filter only You can then replace the cover...

Page 14: ...packed and held available for the FONDIS carrier to collect it Operations and returns must be made with the written agreement of FONDIS after sales service 7 2 TERMS OF APPLICATION OF THE GUARANTEE Th...

Page 15: ...ume of your wine cellar in meters squared ________ FIRST NAME______________________________ LAST NAME_____________________________________ ADDRESS______________________________________________________...