CONTROLS
SCX364 86037150 1/17/07
3-7
7. ACTUATOR SWITCH DECK UP-DOWN
Adjusts the amount of brush pressure to the
floor by raising or lowering the scrub deck.
Use the brush pressure indicator to determine
the correct pressure.
To increase brush pressure, press the bottom
of the switch.
To decrease brush pressure or rise the scrub
deck, press the top of the switch.
8. SOLUTION CONTROL KNOB
Controls solution flow to scrub deck.
To increase flow, rotate knob clockwise.
To decrease flow, rotate knob
counterclockwise.
If the brush motors are turned off or the propel
control levers are in neutral, the flow is
automatically interrupted until the motors are
turned on again. This feature prevents
unintentional draining of the solution tank and
allows the operator to adjust the solution flow
to the scrub deck without resetting each time
the scrubbing operation is interrupted.
9. VACUUM
SWITCH
Controls the vacuum motor.
To start vacuum motor, press the bottom of
the switch.
To stop vacuum motor, press the top of the
switch.
10. SQUEEGEE LIFT LEVER
Raises and lowers the squeegee.
To lower the squeegee, lift the lever from its
raised position.
To raise the squeegee, lift the lever from its
lowered position.
11. SQUEEGEE PITCH ADJUSTMENT KNOB
Adjusts the deflection at the ends of the squeegee.
To increase squeegee blade deflection at the
ends, turn knob counterclockwise.
To decrease squeegee blade deflection at the
ends, turn knob clockwise.
12. SQUEEGEE DEFLECTION ADJUSTMENT
KNOBS
Adjusts the deflection along the entire length of
the squeegee.
To increase squeegee blade deflection along the
entire length, turn the two knobs at the
squeegee ends counter-clockwise.
To decrease squeegee blade deflection along
the entire length, turn the two knobs at the
squeegee ends clockwise.