background image

RECOVERY TANK ASSEMBLY

D-250   98637  11/07/00

14

REF

PART NO.

QTY

DESCRIPTION

SERIAL NO.

FROM

NOTES:

1

05151

1

TUBE ASM, RECOVERY TANK

2

500009

1

LABEL, WARNING

3

260-64A

1

ACCESS COVER CLEAR 6” W/RIM

4

70546

6

SCR, 8 X 3/4 PFHT/S BLK ZINC

5

090-12A

1

FLOAT CAGE ASSY COMPLETE SLIP

6

240-46

1

FLOAT SCREEN ADAPTER 30 DEGREE

7

300-08

1

FL HD WD SCREW PH 6 X 1/2 SS

8

78460

1

TUBE, 1.5 PVC X 16.5

9

04032

1

ADPTR, 1.5 MPT X 1.5 FS PVC

10

320-05

2

VELCRO STRAPS

11

370-06A

1

DUMP VALVE 1-1/2 M THREAD

12

31032

1

ELBOW, 1.5 FS X FS 45D PVC

13

390-26

3

SPACER NYLON 1/4 ID X 1/2 OD

14

110-26B

1

GASKET VAC BRACKET

15

360-24

1

PLATE, VAC

16

87013

13

WASHER, 1/4 ID X 5/8 OD SS

17

35011

1

GASKET, 3/8T 5.7 VAC FAN SEAL

18

065-92

3

VAC SPACER 2 1/4 II STAGE

19A

360-04A

1

VACUUM 110V TWO STAGE 116392-0

19B

360-06

1

VACUUM 116213 220V SM 2 STG

20

70250

1

SCR, 1/4-20 X 3.5 HHCS PLTD

21

87016

3

WASHER, #10 LOCK EXT STAR SS

22

70335

1

SCR, 10-32 X 1/2 PHTR GRN/GRND

23

20063

1

CLAMP, 1.75” WORM GEAR X .312

24

39337

1

HOSE, 1.5 BLK VAC X 24”

25

27508

1

CUFF, VAC HOSE BLU

26

20046

1

CLAMP, 2.25” WORM GEAR

27

880292

1

WIRE, 4” GRN/14 76010 X 76014

28

75334

1

TANK, RECOVERY DB DK GRY

29

70015

2

SCR, 1/4-20 3/4 HHCS SS DL

30

065-25

1

TANK BRACE ASM, D/B

31

70020

2

SCR, 1/4-20 X 1/2 HHCS SS NP

32

40001R

1

HOSEBARB, 1.5 MPT X 1.5

33

39574

1

HOSE ASM, 1/4 HP SLTN 16.5FT

34

150-44A

1

VAC HOSE 16-1/2’ W/CUFFS 1 1/2

35

47356

1

KIT, HOSE ASM W/BAG DOM50

36

150-65

1

HOSE BAG 24” X 36”

Summary of Contents for DOMINATOR D250

Page 1: ...Read these instructions before operating the machine MODEL D250 115V D250IE 230V Prior to Serial No 1000054536 98637 04 25 02 F CARPET EXTRACTOR Operating Instructions ENG ...

Page 2: ...orized service center Do not pull or carry machine by electrical cord use as a handle close a door on cord or pull cord around sharp edges or corners Do not run machine over cord Keep cord away from heated surfaces Do not unplug machine by pulling on cord To unplug grasp the electrical plug not the electrical cord Do not handle the electrical plug or machine with wet hands Do not operate the machi...

Page 3: ...e like extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover Whenever the adaptor is used it must be held in place by a metal screw The D250IE is for use on a nominal 230 volt circuit Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or service person if you ar...

Page 4: ...owing Windsor equipment Deluxe Hand Tool DHT Pile Jogger PJ2A Standard Floor Wands SFW SW SW PRO PROW Wind Blower carpet dryer WB3 Contact an authorized Windsor dealer for assistance in choosing the right equipment GENERAL INFORMATION On heavily soiled carpets or on areas of high foot traffic it may be necessary to use a prespray or traffic lane cleaner applied with a Pro Spray Do not add prespray...

Page 5: ...re adding to the solution tank 6 Turn pump and vacuum switch to the on position 7 Start cleaning NOTES ____________________________ ___________________________________ ___________________________________ ___________________________________ ___________________________________ ___________________________________ ___________________________________ ___________________________________ ________________...

Page 6: ...ater through solution pump when work is complete 10 Empty both tanks and rinse run vacuum s for at least one minute to dry motor s 11 Store with access covers removed to allow tanks to dry PERIODIC MAINTENANCE 1 Twice a month flush a white vinegar solution One quart vinegar to two gallons of water or anti browning solution mixed as directed through the extractor turning pump switch on off several ...

Page 7: ...l pump WARNING The green ground wire must be attached for safe operation See wiring diagram Note When replacing carbon vac motor brushes loosen wire terminal BEFORE removing screws on bracket Important These brushes wear quicker as the length shortens due to increased heat Spring inside brush housing will damage motor if brushes are allowed to wear away completely If armature commutator is not con...

Page 8: ...trical circuit Check building circuit breaker or fuse machine box Faulty power cord Replace Electrical shock Equipment not grounding Follow grounding instructions exactly Receptacle not grounded Contact an electrician to check building s wiring Internal wiring problem Have a trained service technician check machine s wiring Vac motor speed Worn motor brushes Replace varies or doesn t run Motor wor...

Page 9: ...ressure Too much chemical in Check label for correct solution concentration Solution not Solution hose connection Check for positive connection flowing properly Faulty pump Repair or replace Faulty floor tool valve Repair or replace Faulty pump switch Repair TECHNICAL SPECIFICATIONS POWER TYPE ELECTRICAL 115 V 60 Hz 15 Amps per power cable D250 230 V 50 Hz 15 Amps D250IE ELECTRIC VACUUM MOTOR 1 2 ...

Page 10: ...115V WIRING DIAGRAM D 250 98637 11 07 00 10 ...

Page 11: ...230V WIRING DIAGRAM D250 98637 06 19 00 11 ...

Page 12: ...D250 98637 06 19 00 12 THIS PAGE LEFT BLANK INTENTIONALLY ...

Page 13: ...RECOVERY TANK ASSEMBLY D 250 98637 11 07 00 13 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 16 16 20 21 22 23 24 25 26 27 28 29 30 16 31 32 16 19AB 33 34 35 36 ...

Page 14: ...AC 16 87013 13 WASHER 1 4 ID X 5 8 OD SS 17 35011 1 GASKET 3 8T 5 7 VAC FAN SEAL 18 065 92 3 VAC SPACER 2 1 4 II STAGE 19A 360 04A 1 VACUUM 110V TWO STAGE 116392 0 19B 360 06 1 VACUUM 116213 220V SM 2 STG 20 70250 1 SCR 1 4 20 X 3 5 HHCS PLTD 21 87016 3 WASHER 10 LOCK EXT STAR SS 22 70335 1 SCR 10 32 X 1 2 PHTR GRN GRND 23 20063 1 CLAMP 1 75 WORM GEAR X 312 24 39337 1 HOSE 1 5 BLK VAC X 24 25 2750...

Page 15: ... 11 8 12A 13 14 15 16 17 18 19 20 21 22 23 24 25 26A 27 29 30 31 32 33 34 36 35 37 38 8 39 40 41 42 43 44 45 46 47 48 49 50 51 38 8 46 52 53 54 8 38 55 56 57 58 38 59 8 38 60 61 62 63 64 65 66 63 67 68 41 69 70 230V 15 21 20 16 17 24 23 31 12B 13 14 27 26B 25 30 29 28 28 ...

Page 16: ...2 LABEL CIRCUIT INTERUPTER 21 170 31 1 HEATER MATE WARNING TAG 22 73195 2 STRAIN RELIEF 1 2 NPT 48M 23 330 06 1 TOGGLE SWITCH BOOT 24 330 05 1 TOGGLE SWITCH 25 3350 04 1 TOGGLE SWITCH PLATE ON OFF 26 51116 1 LIGHT ASM 115V BRUSH WEAR 27 22046 1 CLIP NEON LAMP 28 500345 1 LABEL DOM3 SWITCH W HEAT 29 57040 2 NUT 1 2 NPT CONDUIT 30 140 11 2 KNOB RT TANK 31 57105 3 NUT 1 4 20 HEX W STAR WASHER 32 8721...

Page 17: ...HUB 57 010 01 1 AXLE ASM LEFT 58 065 28 2 DIAMONDBACK 200 PUMP SUPPORT 59 040 03 1 CASTER SWIVEL 4 SWIVEL 60 290 08 1 SOL SCREEN ACORN W RUB BASE 61 75349 1 TANK SOLUTION DOM 250 DK BLU 62 500378 2 LABEL DOMINATOR 63 280 02 2 RIVIT AL 3 16 X 1 2 CLOSED 64 390 24 2 WASHER 1 4 X 5 8 BONDED NEOPRN 65 140 12 1 KNOB 1 4 20 X 3 4 S S CUPPOINT 66 27912 1 CHAIN ASM 10 BEAD S S W EVES 67 260 71 2 SOLUTION ...

Page 18: ...31A VAC MOTOR ASM 230V UPPER 55360321 13 111B VAC MOTOR ASM 230V LOWER 55360331 15 131B PUMP 200 PSI 115V 5525079 15 168A PUMP 200 PSI 230V 55250791 15 168B SWITCH 5533002 15 142 8 GRAY RUBBER WHEEL 5504006 15 171 WHEEL CAP 1 2 5504007 15 172 4 CASTER 5504003 15 177 SOLUTION TANK KNOB 5514012 15 180 SWITCH PLATE KNOB 5514011 15 141 ACCESS COVER 55260641 13 114 STRAINER 5529008 15 199 SEAL DUMP VAL...

Page 19: ...ty start date is 90 days after date of sale to an authorized Windsor distributor Parts replaced or repaired under warranty are guaranteed for the remainder of the original warranty period 90 DAY WARRANTY EXTENSION AVAILABLE Upon receipt of the Machine Registration Card Windsor will extend the warranty period an additional 90 days from the purchase date Does not include items warranted 90 days for ...

Reviews: