GROUNDING INSTRUCTIONS
CMPS 86290230 02/22/07
2-
3
THIS PRODUCT IS FOR COMMERCIAL USE
ONLY.
ELECTRICAL:
In the USA, this machine operates on a
standard 15 amp 115V, 60 Hz, A.C. power
circuit. The amp, hertz, and voltage are listed
on the data label found on each machine.
Using voltages above or below those indicated
on the data label will cause serious damage to
the motors.
EXTENSION CORDS:
If an extension cord is used, the wire size must
be at least one size larger than the power cord
on the machine, and must be limited to 50 feet
(15.5m) in length.
GROUNDING INSTRUCTIONS:
This appliance must be grounded. If it should
malfunction or break down, grounding provides
a path of least resistance for electric current to
reduce the risk of electric shock. This
appliance is equipped with a cord having an
equipment-grounding conductor and grounding
plug. The plug must be inserted into an
appropriate outlet that is properly installed and
grounded in accordance with all local codes
and ordinances.
This appliance is for use on a nominal 120-volt
circuit, and has a grounded plug that looks like
the plug in “Fig. A”. A temporary adaptor that
looks like the adaptor in “Fig. C” may be used to
connect this plug to a 2-pole receptacle as
shown in “Fig. B”, if a properly grounded outlet
is not available. The temporary adaptor should
be used only until a properly grounded outlet
(Fig. A) can be installed by a qualified
electrician. The green colored rigid ear, lug, or
wire extending from the adaptor must be
connected to a permanent ground such as a
properly grounded outlet box cover. Whenever
the adaptor is used, it must be held in place by
a metal screw.
Improper connection of the equipment-
grounding conductor can result in a risk of
electric shock. Check with a qualified
electrician or service person if you are in
doubt as to whether the outlet is properly
grounded. Do not modify the plug provided
with the appliance - if it will not fit the outlet;
have a proper outlet installed by a qualified
electrician.
GROUND-FAULT CIRCUIT-INTERRUPTER
PROTECTION
This pressure washer is provided with a
(GFCI) built into the plug of the power supply
cord. This device provides additional protection
from the risk of electric shock. Should
replacement of the plug or cord become
necessary, use only identical replacement parts
that include GFCI protection. If the GFCI is not
the AUTOMATIC RESET TYPE, it must be
manually TESTED and RESET each time the
cleaning system is plugged in. Press firmly to
assure internal spring activates switch. Push
“test“ then push “reset”. Motor will not start if
GFCl does not reset. Check circuit breakers or
outlet. If circuit breaker is not tripped and unit
will not reset, contact local service center.
Summary of Contents for COMPASS 10070050
Page 23: ...NOTES CMPS 86290230 02 22 07 4 7 ...
Page 24: ...CONTROLS CMPS 86290230 02 22 07 5 1 ...
Page 26: ...RECOVERY TANK CMPS 86290230 02 22 07 5 3 RECOVERY TANK CMPS 86290230 02 22 07 5 3 ...
Page 28: ...SOLUTION TANK CMPS 86290230 02 22 07 5 5 ...
Page 32: ...WHEELS FRAME CMPS 86290230 02 22 07 5 9 ...
Page 34: ...PUMP CMPS 86290230 04 20 07 6 10 12 4 2 1 3 9 7 8 16 15 13 14 17 18 19 11 13 5 5 11 ...
Page 36: ...PUMP CMPS 86290230 04 20 07 3 2 1 4 5 6 5 13 ...
Page 38: ...TOOLS STANDARD CMPS 86290230 04 20 07 17 3 11 13A 13B 6 4 5 1 2 7 8 9 10 16 5 15 ...
Page 40: ...VAC HOSE RACK CMPSR ONLY CMPS 86290230 04 20 07 5 17 ...
Page 44: ...TOOLS DRY CLEAN OPTION CMPS 86290230 04 20 07 5 21 ...
Page 46: ...TOOLS LOW FLOW SPRAY GUN OPTION CMPS 86290230 04 20 07 5 4 3 1 2 6 5 23 ...
Page 48: ...TOOLS GROUT CLEANER OPTION CMPS 86290230 04 20 07 5 25 ...
Page 50: ...TOOLS HIGH PRESSURE WAND OPTION CMPS 86290230 04 20 07 5 27 ...
Page 52: ...TOOLS CARPET TOOL OPTION CMPS 86290230 04 20 07 5 29 ...
Page 54: ...STORAGE BAG OPTION CMPS 86290230 04 20 07 5 31 ...
Page 56: ...CHEMICAL LOCK OPTION CMPS 86290230 04 20 07 5 33 ...