MAINTENANCE-BATTERIES
86037880 CHARIOT EXTRACTOR 01/16/07
4-4
CHECKING BATTERY SPECIFIC GRAVITY
Use a hydrometer to check the battery specific
gravity.
CHECKING GRAVITY
A. Hydrometer
B. Battery
NOTE: Do not take readings immediately after
adding distilled water, if the water and acid are not
thoroughly mixed, the reading may not be accurate.
Check the hydrometer readings against this chart.
SPECIFIC GRAVITY
@ 80
°
F (27
°
C)
BATTERY CONDITION
1.265 100%
CHARGED
1.225 75%
CHARGED
1.190 50%
CHARGED
1.155 25%
CHARGED
1.120 DISCHARGED
NOTE: If the readings are taken when the battery
electrolyte is any temperature other than 80
°
F
(27°C), the reading must be temperature corrected.
To find the corrected specific gravity reading when
the temperature of the battery electrolyte is other
than 80°F (27°): Add (+) to the specific gravity
reading 0.004 (4 points), for each 10°F (6°C) above
80° (27°C).
Subtract (-) from the specific reading 0.004 (4
points), for each 10°F (6°C) below 80°F (27°C).
CHARGING BATTERIES
When servicing machine,
avoid contact with battery
acid.
Batteries emit hydrogen
gas. Explosion or fire can
result. Keep sparks and open flame away. Keep
covers open when charging.
Wear eye protection and
protective clothing when
working with batteries.
Charge batteries in a well
ventilated area.
Use a 36 volt, 20 amp maximum output DC charger
which will automatically shut off when the batteries
are fully charged.
1.
Stop the machine in a clean, well ventilated area
next to the charger.
2.
Turn “OFF” machine.
FOR SAFETY: Before leaving or servicing
machine; stop on level surface, turn off machine
and remove key.
3.
Remove rear cover, unplug batteries from
machine, unlatch battery tray and pull out to
expose batteries.
Batteries emit hydrogen
gas. Explosion or fire
can result. Keep sparks and open flame away.
Keep covers open when charging.
4.
Check the electrolyte level in each battery cell.
Before charging, add just enough distilled water
to cover the plates. After charging is complete,
add just enough distilled water to bring up the
level to the indicator ring. If the water level is
too high before charging, normal expansion rate
of the electrolyte may cause an overflow
resulting in a loss of battery acid balance and
damage the machine.
Battery Check
Summary of Contents for 10060140
Page 12: ...DRIVE CONTROLS 86037880 CHARIOT EXTRACTOR 01 16 07 3 5 11 9 8 7 6 5 4 3 1 10 2...
Page 22: ...NOTES 86037880 CHARIOT EXTRACTOR 01 16 07 3 15...
Page 49: ...86037880 CHARIOT EXTRACTOR 01 16 07 PARTS...
Page 50: ...BUMPER 86037880 CHARIOT EXTRACTOR 01 16 07 5 1 7 10 9 10 7 11 6 6 2 1 5 1 4 3 8...
Page 56: ...CONTROL PANEL HOUSING 86037880 CHARIOT EXTRACTOR 01 16 07 5 7 4 9 10 8 7 1 11 2 3 3 6 5...
Page 58: ...DECAL 86037880 EXTRACTOR 01 06 09 5 9 4 1 5 3 7 2 8...
Page 86: ...VACUUM 86067880 CHARIOT EXTRACTOR 01 16 07 5 35 8 5 16 17 3 1 10 9 7 14 15 13 12 6 4 2 11...
Page 88: ...VACUUM SHOES 86037880 CHARIOT EXTRACTOR 06 29 09 5 37 14 10 11 12 13 15 8 9 1 7 6 5 4 3 2 16...
Page 94: ...VACUUM HOSES 86037880 CHARIOT EXTRACTOR 01 24 09 5 43 5 7 8 6 4 1 2 3 TO DOME...
Page 98: ...WHEEL REAR 86037880 CHARIOT EXTRACTOR 01 16 07 5 47 1 2 3...
Page 102: ...WIRING COMPONENTS 86037880 CHARIOT EXTRACTOR 02 03 09 5 51 5 9 1 2 3 4 6 4 7 8 12 11 10 13...
Page 117: ...86037880 CHARIOT EXTRACTOR 01 16 07 OPTIONS...
Page 118: ...BACK UP ALARM OPTION 86037880 CHARIOT EXTRACTOR 01 16 07 5 65 2 1 3 4...