NV Solo® operating 1608-UK     

 

©WindowMaster  2007, 2016                             ®WindowMaster is a registered trademark used under licence by WindowMaster Group  

NV Solo

®

  

Control for one room / zone 

Read instruction carefully before proceeding and keep for future reference (translated text). 

 
 

 
 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for NV Solo

Page 1: ...r com www windowmaster com NV Solo install operating 1608 UK WindowMaster 2007 2016 WindowMaster is a registered trademark used under licence by WindowMaster Group NV Solo Control for one room zone Re...

Page 2: ...19 6 2 1 Sensor 19 6 2 2 Holder 20 6 3 Weather station mounting holes 20 6 4 Connecting the weather station 21 6 4 1 Printed circuit board 21 6 4 2 Connecting power 21 7 Control panel 23 7 1 Descript...

Page 3: ...mperature falls below the set indoor temperature or if a rain or wind alarm is registered MANUAL operation The windows are operated manually using the control panel The wind and rain alarm is active i...

Page 4: ...d Battery symbol empty AUTOMATIC operation The window automatically opens and closes as per the selected values for indoor and outdoor temperatures wind speed and rain MANUAL operation The window moto...

Page 5: ...ndow is operated by using the arrow keys the system will revert back to AUTOMATIC operation after 30 minutes If the key has been pressed for operating in MANUAL operation operation will remain in MANU...

Page 6: ...building conditions Press the key on the control panel for at least 3 seconds to get to the programming of values for AUTOMATIC operation When the two symbols and are shown on the left of the display...

Page 7: ...h is why setting the exterior temperature lock out 3 2 is skipped The window can be operated manually and the wind and rain alarms are active if they have been set to active in AUTOMATIC operation poi...

Page 8: ...an active wind alarm is selected the window closes if the wind sensor registers wind speeds greater than the set value The window can still be operated using but will return to AUTOMATIC operation aft...

Page 9: ...ve or not active An active rain alarm prevents water penetration The rain alarm is pre programmed to be active In active the window closes if the rain sensor registers rain The window can still be ope...

Page 10: ...e the values in points 3 1 3 4 have been set save the values SAV save by pressing the key and the display returns automatically to the indoor and outdoor temperatures If is pressed here you will exit...

Page 11: ...nds The two symbols and will be shown on the left side of the display Press the key again for at least 3 seconds CON and the antenna symbols will be shown in the display The basic settings can now be...

Page 12: ...e key If LEA is selected the radio symbol will stop blinking and the radio waves will begin to run Press the orange programming key inside the weather station to establish the radio connection see the...

Page 13: ...al shall be permanent The window remains closed in the event of a rain or wind alarm The control panel is factory set to ON RECOMMENDED SETTING The alarm signal shall stop after 4 minutes Confirm sele...

Page 14: ...s is however conditional on the maximum chain length of the window motor not being exceeded 2 If the temperature is too low and the window is open the window will close modulated until the temperature...

Page 15: ...ks 2 Hold down open until the desired Fixed open position is reached 3 Confirm the selection by pressing the key The display will automatically change to setup for the next parameter SAV 1 The display...

Page 16: ...y pressing the key The display will automatically change to setup for the next parameter control interval time 1 The display shows the control interval time 7 min and the clock blinks 2 Set the time u...

Page 17: ...lear and the clock blinks 2 Confirm the selection by pressing the key The display will automatically change to setup for the next parameter save 1 The display shows save 2 Confirm the selection by pre...

Page 18: ...electric operation It is recommended to grease window hinges at least once a year after installation of the motor unit ATTENTION To avoid personal injury during installation do not connect motor to p...

Page 19: ...ed The weather station must not be overshadowed by buildings trees or similar There must be a free area of at least 60cm below the weather station to allow for correct wind measurement and to avoid it...

Page 20: ...a screwdriver 6 2 2 b Push the holder downwards and out When mounting vertically on the wall place the flat side in toward the wall with the half moon shaped pin upward 6 2 2 c When mounting verticall...

Page 21: ...he small printer on the underside of the box is not damaged during mounting Ensure that the connecting cable between the printed circuit board and the rain sensor is not pulled off or broken during co...

Page 22: ...ection to the operating unit Close the box by pressing the lid firmly onto the bottom of the box The lid must be pushed in with a clear click on both the right and left sides 6 4 2 a Test to ensure th...

Page 23: ...e control panel and the weather station cannot get in contact place the control panel 10cm beside the current location 7 3 Mounting holes on the control panel 7 4 Radio signal During planning consider...

Page 24: ...ather station and the control panel 7 5 a 4 Press the key for 3 secs until the display shows and the antenna symbol 7 5 b 5 Press the key again for at least 3 seconds 6 The display shows CON and the a...

Page 25: ...rain alarm is maintained for 5 minutes after the sensor has dried 7 6 3 Temperature sensor If the values in the display at the side of the symbols outdoor temperature and indoor temperature look fine...

Page 26: ...ction between the control panel and weather station The weather station is not in operation e g there is no power or a radio connection is broken or has not been registered Procedure Register the radi...

Page 27: ...ies AA Mignon LR6 Surrounding temperature 10 C to 50 C Dimensions of control unit 103 x 98 x 28mm WxHxD Frequency 868 2 MHz Note We reserve the right to make technical changes 10 2 Weather station Vol...

Page 28: ...r temperature above C Outdoor temperature lock out below C Wind alarm m s Rain alarm Yes No Opening position cm Run time Sec Control time temperature Sec 10 5 Examples of structures 10 5 a With Motorc...

Page 29: ...29 10 6 Connection diagram for weather station 10 6 1 WUC 102 WUC 160 WSC 304 and WSC 3x0 Standard...

Page 30: ...30 10 6 2 WCC 3x0 Standard...

Page 31: ...s and WSC 3x0 Plus Input configuration guide for WxC Plus versions Local inputs S1 X3 4 or S2 X1 X10 X3 2 Auto close Auto stop X3 1 Auto open Auto stop Input example Active function Inactive function...