Use, Care, and Installation Guide

www.windcrestcnp.com

Model number: 

Serial Number: 

Date of Purchase: 

Sales Dealer: 

SEP12.0302 © 2012 Wind Crest CNP Industries, Inc.

READ AND SAVE THESE INSTRUCTIONS

UIX2916S

UIX3816S

Summary of Contents for UIX2916S

Page 1: ...e Care and Installation Guide www windcrestcnp com Model number Serial Number Date of Purchase Sales Dealer SEP12 0302 2012 Wind Crest CNP Industries Inc READ AND SAVE THESE INSTRUCTIONS UIX2916S UIX3816S ...

Page 2: ...www windcrestcnp com ...

Page 3: ...eight Clearance 6 Ducting Options 7 Specifications 8 Electrical 9 Installing the Insert 10 VEN111I Dual Internal Blower Kit 11 12 FEATURES CONTROLS Slide Controls 13 MAINTENANCE Cleaning and Installing Filters 14 Lights 15 TROUBLESHOOTING 16 LIST OF PARTS AND ACCESSORIES 17 Table of Contents ...

Page 4: ...kware and utensils appropriate for the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP ...

Page 5: ...e and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate Do not ground to a gas pipe Check with a qualified el...

Page 6: ...pre installed 1 1200CFM Dual internal blower pre installed 1 8 round adapter 1 10 round adapter 1 Hardware package 1 Hardware package HARDWARE PACKAGE CONTENTS PARTS NOT SUPPLIED Ducting conduit and all installation tools Cable connector if required by local codes Dual internal blower kit VEN111I UIX2916S only Optional stainless steel hood liner Dual blower kit includes blower plate and 1 blower B...

Page 7: ...t Ft 6 Round straight 1 Ft x Ft Subtotal column 1 Duct pieces T otal Equivalent number length x used 6 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 10 Round 900 elbow 15 Ft x Ft 7 10 7 10 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 Round roof cap 30 Ft x Ft 7 10 Round roof cap 30 Ft x Ft Subtotal column 2 Subtotal column 1 Total ductwork 6 roundto 3 1 4 x 10 rect transiti...

Page 8: ... are required install as far away from hood duct output and as far apart between the two as possible Minimum mount height between range top to hood bottom should be no less than 30 Maximum mount height should be no higher than 36 It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be h...

Page 9: ...ll exhaust must be ducted to the outside Use metal ductwork only Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Some Ducting Options Installation Ducting Options side wall cap w gravity damper side wall cap w gravity damper Soffit or crawl space Roof Pitch w Flashing Cap ...

Page 10: ...1 1 2 CL elec k o UIX2916S top UIX2916S front UIX2916S UIX3816S side 5 or 1 7 7 8 or 5 7 8 11 7 16 14 11 16 15 13 16 4 3 8 CL 33 1 8 14 3 4 34 5 8 38 7 16 11 7 16 4 3 4 2 3 8 6 1 2 CL UIX3816S front UIX3816S top 9 7 8 2 5 8 A elec k o 7 14 11 16 15 13 16 11 7 16 4 1 2 A 8 round adapter only needed if using dual internal blower kit 6 round collar is standard and requires no adapter ...

Page 11: ...ling local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire w ground Please also refer Electrical Diagram labeled on product Cable Lock A cable locking connector not supplied might also be required by loc...

Page 12: ...nless steel screws 1 in each corner see FIG 2 note Wood blocking may need to be added to cabinet base if additional support is needed 6 Install duct work and seal with duct tape 7 Install electrical 8 Remove all packing material before using insert Switch power on and check for leaks around duct tape 9 Install decorative mesh filters for UIX2916S or baffle filters for UIX3816S See page 14 for more...

Page 13: ...ower capacitor box 1 Disconnect single blower wire from inside of the insert 2 Remove support screw from top of insert near the back Remove 2 screws holding blower plate to insert and pull blower towards front of hood to release from internal bracket 3 Unscrew 4 screws holding blower to blower plate and remove blower Remove metal damper from blower Discard single blower plate 4 Picture of VEN111I ...

Page 14: ...ect 8 round duct work For UIX3816S install 10 round adapter included with insert on top of insert and secure with 4 M4x8 screws Connect 10 round duct work note The 8 and 10 round adapters are fitted with a metal damper to prevent outside airflow from entering the kitchen The 6 round single blower is also fitted with a metal damper If using the VEN111I dual blower kit the metal damper from the 6 ro...

Page 15: ...s BLOWER ON OFF SPEED SELECTION 0 is off I is low speed II is medium speed and III is high speed LIGHTS BRIGHT DIM OFF 0 is off I is dim and II is bright 1 2 0 I I I I I I Blower On Off Speed Selection 1 Lights Bright Dim Off 2 0 I I I ...

Page 16: ...a micro fiber or clean cotton cloth and with the grain Decorative Mesh and Baffle Filters The filters are intended to trap residue and grease from cooking Although the filters should never need replacing they are required to be cleaned every 30 days or more often depending on cooking habits Filters may be placed in dishwasher at low heat or soaked in hot soapy water Dry filters and re install befo...

Page 17: ...ounter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach a glass suction cup approximately the diameter of the bulb or use a rubber latex glove and turn counter clockwise Replacement bulbs are available at specialty lighting stores Purchase type MR16 GU 10 35W halogen For WindCrest part numbers please turn...

Page 18: ...tion properly after the thermally protected system cool down 3 Damaged condenser 3 Change the condenser The unit is vibrating 1 The motor is not secure in place 1 Tighten the motor in place 2 Damaged blower wheel 2 Change the blower wheel 3 The hood is not secured in place 3 Check the installation of the hood The motor is working but the lights are not 1 Defective halogen bulb 1 Change the halogen...

Page 19: ...each 11271 00 Baffle Filter each 11272 00 Optional Accessories Dual blower kit UIX2916S only VEN111I Liner 36 UIX2916S UL2936S Liner 42 UIX2916S UL2942S Liner 48 UIX3816S UL3848S Liner 54 UIX3816S UL3854S Liner 60 UIX3816S UL3860S To order parts call us at 1 877 387 6721 List of Parts and Accessories ...

Page 20: ... agency or use of unauthorized parts 2 Service visits to teach you how to use the appliance 3 Correct installation related problems you are responsible for providing electrical wiring and other connection items 4 Reset circuit breakers or replace fuses 5 Damage caused by abuse accident alteration misuse and local code violations 6 Failure due to other than normal house use You may also write to us...