![Wincor Nixdorf BA71 User Manual Download Page 35](http://html.mh-extra.com/html/wincor-nixdorf/ba71/ba71_user-manual_984958035.webp)
In order to be able to install the TFT controller, you must first remove the
metal panel that covers the free slots by loosening the screw.
Set the jumper for the I/O addresses and the interrupt requests on the
COM board. It is strictly necessary to avoid conflicts, so please inform
yourself of already existing settings.
Plug the TFT COM board into the corresponding AT terminal and plug the
TFT controller into the PCI terminal. Connect the COM/5 and COM/6 inter-
faces of the COM board with the TFT controller.
Push the plastic cramp horizontal
into the TFT controller (1) and into
the COM (2) board at the same time.
Secure the controller into place by re-
tightening the screw.
Installation
Metal tracks
Speaker connector
➊
➋