Test Request
A self test is performed. This command causes no new enumeration.
Command: 00H, 10H, 00H, .., 00H
Status Request
Status is requested.
Command: 00H, 20H, 00H, .., 00H
Reset Request
A reset causes a new login and thus enumeration of the device with all
sub-devices. Therefore, there is no corresponding response to the Reset
Request.
Command: 00H, 40H, 00H, .., 00H
Read Config Response
Response: Length Byte, Status Byte 0, Status Byte 1,
Status Byte2 (s. Status Response)
“Pn1;Pn2;Pn3;Pn4;Pn5;Pn6;Pn7“
Pn1: type of display (1 digit ASCII, e.g. “2")
Pn2: actual code page (4 digits ASCII, e.g. “0852“)
Pn3: country code (2 digits ASCII, e.g. “02“)
Pn4: number of lines (1 digit ASCII, e.g. “2“)
Pn5: columns/line (2 digits ASCII, e.g. “20“)
Pn6: code page loaded in Space-Page (4 digits
ASCII, e.g. “0850")
Pn7: serial number (10 chars ASCII, e.g.
"N000000001")
Note
: Pn6 rsp. Pn7 may be omitted in case the Space Page is empty or no
serial number burnt into the device.
CONTROL SEQUENCES