Winco WC10000VE Installation And Operator'S Manual Download Page 2

2

REV B

60706-232

TABLE OF CONTENTS

SAVE THESE INSTRUCTIONS 

2

SPECIFICATIONS 2

GENERATOR

ENGINE

SAFETY INFORMATION 

3

ANSI SAFETY DEFINITIONS

TESTING POLICY 

4

INTRODUCTION 4

INTENDED USES

RESTRICTED USES

UNIT CAPABILITIES 

4

GENERATOR CONNECTIONS

STARTING ELECTRIC MOTORS

PREPARING THE UNIT  

5

UNPACKING

LUBRICATION

OIL RECOMMENDATIONS

OIL ALERT SYSTEM

GASOLINE

CONSERV-R

®

 IDLE CONTROL

BATTERY INSTALLATION

BATTERY CHARGING

OPTIONAL DOLLY KIT

INITIAL START UP 

7

BASIC OPERATION

STARTING HINTS

CONNECTING THE LOADS 

8

APPLYING THE LOADS

GROUNDING

WIRING

ENGINE CARE 

9

MAINTENANCE SCHEDULE

CHANGING THE OIL

GENERATOR CARE 

10

EXERCISING THE GENERATOR

GENERATOR MAINTENANCE

DUAL ELEMENT AIR FILTER

SPARK PLUG

CARBON CANISTER

CLEANING

CONTROL PANEL WIRING DIAGRAM 

11

TROUBLESHOOTING 11

24 MONTH LIMITED WARRANTY 

12

SAVE THESE INSTRUCTIONS

This manual contains important instructions that should be followed 

during installation and maintenance of the generator. Read and 

understand all instructions in the manual before starting and operating 

the generator.

USING THIS MANUAL

Congratulations on your choice of a WINCO generator. You have 

selected a high-quality, precision-engineered generator designed and 

tested to give you years of satisfactory service.

To get the best performance from your new generator, it is important 

that you carefully read and follow the operating instructions in this 

manual.

Should you experience a problem please follow the “Troubleshooting 

Tables” near the end of this manual. The warranty listed in the manual 

describes what you can expect from WINCO should you need service 

assistance in the future.

COPY YOUR MODEL AND SERIAL NUMBER HERE

No other WINCO generator has the same serial number as yours. 

If you should ever need to contact us on this unit, it will help us to 

respond to your needs faster.

MODEL __________________________________________________

SERIAL NUMBER _________________________________________ 

PURCHASE DATE _________________________________________

DEALER NAME ___________________________________________

DEALER PHONE # ________________________________________

SPECIFICATIONS

GENERATOR

Model     WC10000VE/E-G

Surge 

Watts 

   10,500

Continuous 

Watts 

  9,600

Volts 

     120/240

Amps     80/40

Generator Manufacturer  

Mecc Alte Spa  

Generator Model Number  S20W-130/A

Part 

Number 

   16428-002 

Rotor Resistance   

 

5.67 Ohms

Stator Resistance   

 

0.145 Ohms

Cap Winding Resistance  

1.31 Ohms

Capacitors    40 

mF

Capacitor Part Number   

16346-312

Summary of Contents for WC10000VE

Page 1: ...WINCO INC 225 S CORDOVA AVE LE CENTER MN 56057 507 357 6821 SERVICE DEPT 507 357 6831 www wincogen com INSTALLATION AND OPERATORS WC10000VE E G GENERATOR MANUAL...

Page 2: ...ou have selected a high quality precision engineered generator designed and tested to give you years of satisfactory service To get the best performance from your new generator it is important that yo...

Page 3: ...d know its proper use Fire extinguishers rated ABC by NFPA are appropriate E Store fuel only in an approved container and only in a well ventilated area F Follow local codes for closeness to combustib...

Page 4: ...this 9 600 watt rated output generator A B represent the 120 volt output legs of this generator Up to 4 800 watts at 120 volts 40 Amps can be drawn from the receptacles attached to either A or B outp...

Page 5: ...system The necessity of using the correct oil and keep ing the crankcase full cannot be overemphasized Engine failures resulting from inadequate or improper lubricant are considered abuse and not cove...

Page 6: ...an 5 to 10 Watts they will not turn the Conserv R off resulting in low voltage being supplied to them This low voltage can do permanent damage to these appliances BATTERY INSTALLATION This engine gene...

Page 7: ...TICE ENGINE START LOCKOUT This unit will not start if it is low on oil The lu bricating oil level must be at the full mark before the engine will start and run BASIC OPERATION MANUAL STARTING Refer to...

Page 8: ...odically to ensure continued proper operation of the generating plant and appliances If the generator is not equipped with a voltmeter it can be checked with a portable meter CONNECTING THE LOADS APPL...

Page 9: ...d by a licensed electrician according to all applicable codes The electrician will move the critical circuits to be powered during the outage to the emergency panel Keep in mind only a limited amount...

Page 10: ...dual oil may have remained in the engine Always use the dipstick when lling the engine with oil to prevent over lling h Replace ller plug I Start the engine and warm it up J After warming up the engin...

Page 11: ...ufflers equipped with spark arresters the spark arrester must be removed every 50 hours for cleaning and inspection Replace if damaged TROUBLESHOOTING Problem Possible Causes Won t start Low oil level...

Page 12: ...rticular purpose are limited to 24 months from date of purchase In no event is WINCO liable for incidental or consequential damages Note Some states do not allow limitation on the duration of implied...

Reviews: