background image

2

OPM-122

REV C

TABLE OF CONTENTS

TESTING POLICY 

2

SPECIFICATIONS 3

TB2400/E

TB4800/A

TB7200/C

INTRODUCTION 3

SAFETY 4

IMPORTANT SAFETY INSTRUCTIONS

ANSI SAFETY DEFINITIONS

CALIFORNIA PROPOSITION 65

UNIT CAPABILITIES 

5

GENERATOR CONNECTIONS

STARTING ELECTRIC MOTORS 

5

PREPARING THE UNIT 

6

UNPACKING

CONNECTING THE LOADS 

6

APPLYING THE LOAD

UNIT INSTALLATION 

7

PLAN THE INSTALLATION

MOUNTING

TROUBLESHOOTING 8

WIRING SCHEMATICS 

9

TB2400

TB4800

TB7200

12 MONTH LIMITED WARRANTY 

12

SAVE THESE INSTRUCTIONS

This manual contains important instructions that should be followed 

during installation and maintenance of the generator. Read and 

understand all instructions in the manual before starting and operating 

the generator.

USING THIS MANUAL

Congratulations on your choice of a WINCO generator. You have 

selected a high-quality, precision-engineered generator designed and 

tested to give you years of satisfactory service.

To get the best performance from your new generator, it is important 

that you carefully read and follow the operating instructions in this 

manual.

Should you experience a problem please follow the “Troubleshooting 

Tables” near the end of this manual. The warranty listed in the manual 

describes what you can expect from WINCO should you need service 

assistance in the future.

COPY YOUR MODEL AND SERIAL NUMBER HERE

No other WINCO generator has the same serial number as yours. It 

is important that your record the number and other vital information 

here. If you should ever need to contact us on this unit, it will help us to 

respond to your needs faster.

MODEL __________________________________________________

SERIAL NUMBER _________________________________________ 

PURCHASE DATE _________________________________________

DEALER NAME ___________________________________________

DEALER PHONE # ________________________________________

TESTING POLICY

Before any generator is shipped from the factory, it is fully checked 

for performance. The generator is loaded to its full capacity, and the 

voltage, current, and frequency are carefully checked.

Rated output of generator is based on engineering tests of typical units, 

and is subject to, and limited by, the temperature, altitude, fuel, and 

other conditions specified by the manufacturer of applicable engines.

Summary of Contents for TB2400/E

Page 1: ...WINCO INC 225 S CORDOVA AVE LE CENTER MN 56057 507 357 6821 SERVICE DEPT 507 357 6831 wincogen com INSTALLATION AND OPERATORS TB2400 E TB4800 A TB7200 C TWO BEARING GENERATORS MANUAL TB7200...

Page 2: ...ting instructions in this manual Should you experience a problem please follow the Troubleshooting Tables near the end of this manual The warranty listed in the manual describes what you can expect fr...

Page 3: ...Amps 60 30 Receptacles 1 NEMA L14 30R Moisture Protection IP 23 Generator End Manufacturer Mecc Alte Model S20W 110 2 Capacitor 35 F Capacitor Part Number 16346 312 INTRODUCTION These generators are...

Page 4: ...tructions in this manual could result in serious injury or death Keep this manual available for future reference ANSI SAFETY DEFINITIONS DANGER DANGER indicates an imminently hazardous situation which...

Page 5: ...ctric motor up to operating speed The generator responds with high initial starting current but the engine speed drops sharply The overload may stall the engine If allowed to operate at very low speed...

Page 6: ...E DO IT YOURSELF JOB For your safety all wiring must be done by a qualified electrician and conform to the National Electric Code and all state and local codes and regulations Check with local authori...

Page 7: ...voltage should be checked periodically to ensure proper operation of the generator and appliances UNIT INSTALLATION Plans for installation should be prepared with proper attention to mechanical and e...

Page 8: ...ective stator 4 Defective rotor Output voltage too high Engine speed too high Generator overheating 1 Generator overloaded 2 Poor ventilation No output voltage 1 Short in load 2 Broken or loose wire 3...

Page 9: ...9 OPM 122 REV C WIRING SCHEMATICS TB2400 GND GND G1 G1 G1 N N...

Page 10: ...10 OPM 122 REV C TB4800 2 N N N G1 G1 G1 G2 G2 G2 GND GND GND GND...

Page 11: ...11 OPM 122 REV C 2 G1 G1 G2 G2 N N GND GND GND TB7200...

Page 12: ...ranty does not cover travel time mileage or labor for removal or re installation of WINCO product from its application Normal wear and tear Costs of rental equipment WINCO does not warrant engines Eng...