background image

12

REV B

60706-231

 38.000 

 25.042 

2

1

3

 21.660 

5

9

8

6

ITEM NO.

PartNo

DESCRIPTION

QTY.

1

19022-200

RECEPTACLE  BOX ASSEMBLY

1

2

19022-055

ENGINE AND BASE ASSEMBLY

1

3

19022-011

DECAL INSTALLATION

1

4

100046-504 CARTON 30-50 PTO HSC/FOL TW 

43-1/2 X 27-3/8 X 26 ECT 80

1

5

21698-001

10-16 X .375 TORX SCREW

1

6

16249-000

.3125-18 FLANGE NUT

2

7

60706-231

OPERATOR MANUAL

1

8

526-000

5/16 FLAT WASHER

2

9

467-000

HHCS 5/16-18X.75  

2

REVISIONS

REV

IRN

DESCRIPTION

DATE

BY

APP'D

A

ORIGINAL

MVW

B

REDESIGNED RECEPTACLE BOX

6/20/12

PJY

MVW

C

3630

60706-231 ADDED

3/24/2015

KS

DRC

D

5271

REPLACED 473-000 WITH 467-000 ADDED 526-000

5/17/2016

RJD

ZJF

CHK'D BY

ENG APPR.

TITLE:

EC22000VE

DATE

DATE

DATE

DRAWN BY

MODEL:

PART:

PJY

THIS DRAWING CONTAINS 

PROPRIETARY

 INFORMATION BELONGING

 TO WINCO, 

UNAUTHORIZED USE IS 

PROHIBITED

ALL DIMESNIONS INCH

4/27/2012

EC22000VE/A

R

19022-000

19022-000

PJY

4/27/2012

TOLERANCE:

+/- 0.0625 DECIMAL

+/- 1 DEG ANGULAR

 21.161 

19018-000

PART:

4/26/2012

TOLERANCE:

MODEL:

CHK'D BY

ENG APPR.

TITLE:

EC18000VE

DATE

DATE

+/- 0.0625 DECIMAL

1901

8-000

EC18000VE

DATE

ALL DIMESNIONS INCH

R

PJY

DRAWN BY

PJY

4/26/2012

THIS DRAWING CONTAINS 

PROPRIETARY

 INFORMATION BELONGING

 TO WINCO, 

UNAUTHORIZED USE IS 

PROHIBITED

+/- 1 DEG ANGULAR

ITEM 

NO.

PART NUMBER

DESCRIPTION

QTY.

1

19018-011

DECAL INSTALLATION

1

2

19055-000

ENGINE AND BASE

1

3

19018-200

RECEPTACLE ASS'Y

1

4

100046-504

CARTON 30-50 PTO HSC/FOL TW 43-

1/2 X 27-3/8 X 26 ECT 80

1

5

60706-231

OPR MANUAL EC18 & EC22

1

REVISIONS

REV

IRN

DESCRIPTION

DATE

BY

APP'D

A

ORIGINAL

B

CHANGED DECAL SET FROM 15715-057 TO 19018-011

4/26/12

PJY

CLR

C

ADDED SHIPPING CARTON TO BILL

4/27/12

PJY

CLR

D

REMOVED FUEL KIT FROM BILL

5/3/12

PJY

CLR

E

3706

60706-231 ADDED

4/7/2015

KS

DRC

2

 18.641 

 34.000 

 32.685 

 24.059 

1

OUTLINE DRAWINGS

EC18000VE

EC22000VE

Summary of Contents for EC18000VE/A

Page 1: ...WINCO INC 225 S CORDOVA AVE LE CENTER MN 56057 507 357 6821 SERVICE DEPT 507 357 6831 www wincogen com INSTALLATION AND OPERATORS EC18000VE A EC22000VE A GENERATORS MANUAL...

Page 2: ...lected a high quality precision engineered generator designed and tested to give you years of satisfactory service To get the best performance from your new generator it is important that you carefull...

Page 3: ...0 006 in Exhaust Valve Clearance 0 007 0 009 in Oil Capacity 78 80 oz 2 4 2 5 qts EC22000VE Starting Watts 22 000 22 000 22 000 22 000 Running Watts 19 000 19 000 19 000 19 000 Volts 120 240 120 208...

Page 4: ...area clean A Remove all grease ice snow or materials that create slippery conditions around the unit B Remove any rags or other materials that could create a potential fire hazard C Carefully clean up...

Page 5: ...burn out in a short time The generator winding might also be damaged CAUTION EQUIPMENT DAMAGE Running the generator set under these conditions may result in damage to the generator stator as well as...

Page 6: ...greater lift is required it may be necessary to provide an additional electric fuel pump to ensure the engine get a sufficient flow of fuel 2 EPA regulations require the installation of a carbon cani...

Page 7: ...parks flames and burning cigarettes away from the battery Ventilate the area when charging or using the battery in an enclosed space Lead acid batteries contain sulfuric acid which causes severe burns...

Page 8: ...Although individual units and models vary slightly the normal voltage and frequency of the engine generator described in this manual are approximately as follows under varying loads LOAD vs OUTPUT Ge...

Page 9: ...allations will require different grounding requirements Depending on your installation ensure that the ground meets your governing codes WIRING For your safety all wiring must be done by a qualified e...

Page 10: ...or the proper grade of oil based on your operating temperature NOTE This engine requires 78 to 80 ounces of oil if it is completely drained Use caution when re lling the engine as some residual oil ma...

Page 11: ...Defective rotor field Defective capacitor EC18000VE Circuit breaker trips Defective load Defective receptacle Excessive load Voltage too high Engine speed is too high Generator overheating Overloaded...

Page 12: ...ED USE IS PROHIBITED ALL DIMESNIONS INCH 4 27 2012 EC22000VE A R 19022 000 19022 000 PJY 4 27 2012 TOLERANCE 0 0625 DECIMAL 1 DEG ANGULAR 21 161 19018 000 PART 4 26 2012 TOLERANCE MODEL CHK D BY ENG A...

Page 13: ...13 REV B 60706 231 EC18000VE EC22000VE DISTRIBUTION WIRING SCHEMATICS 120 240 SINGLE PHASE 120 208 120 240 THREE PHASE 277 480 THREE PHASE...

Page 14: ...OW WYE THREE PHASE LO 120 208 VOLTS THREE PHASE HIGH WYE 277 480 VOLTS Page 14 0210 10 REV B 60706 197 EE PHASE AC WIRING H AND LOW WYE THREE PHASE LOW WYE 120 208 VOLTS E HIGH WYE S EC22000VE AC WIRI...

Page 15: ...REV B THREE PHASE AC WIRING D SINGLE PHASE AC WIRING SINGLE PHASE 120 240 VOLTS THREE PHASE D 120 240 VOLTS E PHASE AC WIRING DELTA E PHASE AC WIRING GLE PHASE 240 VOLTS THREE PHASE DELTA 120 240 VOLT...

Page 16: ...rticular purpose are limited to 24 months from date of purchase In no event is WINCO liable for incidental or consequential damages Note Some states do not allow limitation on the duration of implied...