W91570DN SERIES
Publication Release Date: May 1997
- 15 -
Revision A2
Auto Redial
If ARD pin = V
DD
or V
SS
, the auto redial function is selected:
OFF HOOK
(or
ON HOOK
&
HFI
¡õ
),
OKR
waiting interval
Time Zone (C)
Auto dialing
Time Zone (A)
Pause
Break
Time
Time
Pause
Break
Time Zone (A)
waiting interval
Auto dialing
Time Zone (B)
Time
Time
repeat till
n-1 times.
Time Zone (B)
1. During time zone (B) the keypads are inhibited, and in time zone (A), (C) the auto redial can be
interrupted by pressing any keypad or by going off-hook.
2. The visible dialing number will be blinking during the waiting time interval.
3. If OKR is the first key-in after off-hook or handfree then the first break and pause time will be
ignored.
4. The following show examples to interrupt auto redial function:
OFF HOOK
(or
ON HOOK
&
HFI
¡õ
),
OKR
,
Any Keypad
(at break time and
waiting interval)
5. If
ON HOOK
&
HFI
¡õ
,
OKR
,
OFF HOOK
a. When in time zome (A) or (C), the auto-redial function will be interrupted and changed to hook
mode after
OFF HOOK
b. When in time zome (B), the auto-redial functiion will continue and changed to hook mode after
OFF HOOK
6. If
ON HOOK
&
HFI
¡õ
,
OKR
, HFI
¡õ
(any time) is entered, the dialer will be off-line.
7. The auto redial function timing diagram is shown in Figure 11(a), 11(b).
8. The calling time will auto-count when the auto-redial function is interrupted in break time zone (A)
and (C).
TIM
OFF HOOK
(or
ON HOOK
&
HFI
¡õ
),
D1
,
D2
, ...,
Dn
(or
Redialing
or
Repertory dialing 1
), CONVERSATION
1. If no key is pressed after dialing is finished, the LCD will display counting time after 6 seconds.
2. If the dialing sequence D1, D2, ..., Dn has not finished, TIM will be ignored.
3. The timer will be initialized by flash and auto redial.