7
The
day programme
saves the ventilation behaviour of a single day. This
can be used when there is an increased demand for ventilation or if you
want to ventilate your holiday flat regularly even when you are not there
(minimum ventilation).
Manual opening and closing is always possible even when neither of the
two ventilation programmes is active. If you enter a manual command
even though the automatic ventilation is running, this command will be
valid for a defined period of time (manual operation time) and the FLS
will subsequently return to automatic ventilation. Safety criteria (weather
conditions at the window) are always considered, however, unless you
want to force the window to open (see chapter 4.5).
It is also possible to open the window completely (see chapter 5).
If the FLS window ventilation system ventilates too much or too little, you
can adjust the ventilation intensity of the FLS yourself.
If you want to ventilate more, press the two buttons of the manual switch
and the “Open” button of the remote control unit at the same time. This
increases the ventilation unit intensity by 1 stage.
If you want to ventilate less, press the two buttons of the manual switch
and the “Close” button of the remote control unit at the same time. This
decreases the ventilation unit intensity by 1 stage.
A range of ± 3 stages is available for adjustment. Adjustments that have
been performed are not displayed, however.
3.2
Adjustment of the ventilation intensity