WIN Enterprises PL-10510 User Manual Download Page 5

 

 

WIN Enterprises, Inc

 

 

 

 

1.2 Specifications 

 

Processor 

System  

CPU 

Intel® Celeron™ processor J1900 (Bay Trail-D), 
E3800 (Bay Trail-I) Processors

 

BIOS 

AMI UEFI BIOS 

Memory  

Technology 

Un-buffered and Non-ECC DDR3L 1333MHz memory.

 

Capacity 

Up to 8GB with one SO-DIMM socket 

Ethernet

 

GbE Ethernet 

Six Copper GbE ports, Intel I211, PCI-E x1 

LAN bypass 

Two pairs bypass between LAN1, LAN2 and LAN3, 
LAN4 

Storage  

SATA HDD 

One internal 2.5

 or one internal 3.5

 SATA HDD bay 

CompactFlash™ 
Socket 

one CompactFlash

TM 

Type II 

I/O  

USB 

Rear: Two external USB2.0 
Two internal 5x2 pin header 

Serial 

One RJ45 Console port (COM1) 

Expansion

 

PCIe  Slot  

One Standard PCI-E x1 connector (Optional)   

Power Supply

 

Watt 

60W power supply 

Mechanical 

 

&   Environmental  

Form Factor 

1U Rack-mount 

LED 

1 x Status LED (Green),   
1 x HDD LED (Red),   
1 x Power LED (Green), 
1 x Bypass LED (Yellow) 

Dimensions 

W x D x H

 

432mm (W) x 270mm (D) x 44mm (H)   
(17

 W x 8

 D x 1.7

 H) 

Operating 
Temperature 

Operating: 0 ~ 40°C ( 32 ~ 104°F ) 

Storage 
Temperature 

-20 ~ 75°C (-4 ~ 167°F) 

Humidity 

10 ~ 85% relative humidity, non-operating, 
non-condensing 

Certification 

CE/FCC 

 

Summary of Contents for PL-10510

Page 1: ...N Enterprises Inc 1 Networking Appliance User s Manual Version 1 3 1U Rack mount Intel Celeron codename Bay Trail Network System Six Copper GbE CF SATA PCIe and Bypass PL 10510 Custom Embedded Solutio...

Page 2: ...al business Machine Corporation Award is a trademark of Award Software International Inc Intel is a trademark of Intel RTL is a trademark of Realtek VIA is a trademark of VIA Technologies Inc Microsof...

Page 3: ...Chapter 3 BIOS Setup 21 3 1 Quick Setup 21 3 2 Entering the BIOS Setup Utility 21 3 3 Menu Options 23 3 4 Advanced Menu 23 3 5 Chipset Menu 41 3 6 Security Menu 43 3 7 Boot Menu 44 3 8 Exit Menu 47 Ch...

Page 4: ...ot with memory up to 8 GB In order to provide the best network performance and utilization the expansive storage interfaces include 2 5 SATA HDD and CompactFlash To enhance the network security perfor...

Page 5: ...al 3 5 SATA HDD bay CompactFlash Socket one CompactFlash TM Type II I O USB Rear Two external USB2 0 Two internal 5x2 pin header Serial One RJ45 Console port COM1 Expansion PCIe Slot One Standard PCI...

Page 6: ...e CB DB9200 01 Null modem cable CB IVGA01 01 VGA cable CB IPS200 00 KB MS cable CB IUSB01 00 USB cable 1 4 Packaging Please make sure that the following items have been included in the package before...

Page 7: ...nts Electrostatic discharge can be easily damage the PL 10510 appliance Do not remove the anti static packing until you are ready to install the PL 10510 appliance Ground yourself before removing any...

Page 8: ...WIN Enterprises Inc 8 1 6 System Layout PL 10510 Front Side Layout PL 10510 System Layout Layout...

Page 9: ...WIN Enterprises Inc 9 1 7 Board Dimensions...

Page 10: ...WIN Enterprises Inc 10 Chapter 2 Connector Jumper Configuration 2 1 Connector Jumper Locations and Definitions...

Page 11: ...ayout with LED16 CN5 USB Port 2 3 Pin Header CN22 USB Port 0 1 CN6 VGA Pin Header CN23 DC IN Pin Header Co Layout with CN31 CN7 SATA Power Connector CN24 LAN1 CN8 KEY PAD Pin Header CN25 LAN2 CN9 LCM...

Page 12: ...Defined and Jumper Settings Connector Location Defined CN1 CN2 CN3 System CPU FAN Pin Define 1 Ground 2 12V 3 Speed Detect CN7 SATA PWR 1 2 3 4 Pin Define 1 12V 2 GND 3 GND 4 5V CN8 Keypad header Pin...

Page 13: ...3 P_AFD 4 NC 5 P_INIT 6 P_SLIN 7 LCM_PD1 8 LCM_PD0 9 LCM_PD3 10 LCM_PD2 11 LCM_PD5 12 LCM_PD4 13 LCM_PD7 14 LCM_PD6 15 LCM_BK_CTRL 16 BK_CTRLP CN10 SPI Pin Header Pin Define Pin Define 1 1 8V 2 GND 3...

Page 14: ...header Pin Define Pin Define 1 DCD 2 DSR 3 SIN 4 RTS 5 SOUT 6 CTS 7 DTR 8 RI 9 Ground 10 N A CN13 GPIO Pin Define Pin Define 1 3 3V 2 SIO_GP50 3 SIO_GP51 4 SIO_GP52 5 SIO_GP53 6 SIO_GP54 7 SIO_GP55 8...

Page 15: ...5V 28 GND 26 3 3VAUX 24 PERST 22 RESERVED 20 GND 18 RESERVED 16 RESERVED 14 RESERVED 12 RESERVED 10 RESERVED 8 1 5V 6 GND 4 Pin Define Pin Define 1 WAKE 2 3 3V 3 Reserved 4 GND 5 Reserved 6 1 5V 7 CL...

Page 16: ...Header Pin Define Pin Define 1 3 3V 2 AD 0 3 AD1 4 AD 2 5 AD 3 6 Frame 7 PCIERST 8 5V 9 CLOCK 10 PME 11 GND 12 13 SERIRQ 14 DRQ CN18 PS2 KB MS Pin Header Pin Define Pin Define 1 KCLK 2 MCLK 3 KDAT 4 M...

Page 17: ...TA0 3 DATA0 4 GND 5 5V 6 DATA1 7 DATA1 8 GND CN24 29 LAN RJ 45 Connector Pin Define 1 TX 2 TX 3 RX 4 Chassis Ground 5 Chassis Ground 6 RX 7 Chassis Ground 8 Chassis Ground D1 Speed indicated LED 1 Gbp...

Page 18: ...WIN Enterprises Inc 18 CN30 COM1 Console Connector RJ45 Pin Define 1 CTS 2 DTR 3 TXD 4 GND 5 GND 6 RXD 7 DSR 8 RTS CN31 DC 12V Power Jack 2Pin 1 1 2 2 Pin Define Pin Define 1 12V 2 GND...

Page 19: ...2 Normal Operation 2 3 Clear CMOS JP2 LAN1 LAN2 bypass select Pin Setting 1 2 By pass mode 2 3 Normal operation JP3 LAN3 LAN4 bypass select Pin Setting 1 2 By pass mode 2 3 Normal operation JP4 Reset...

Page 20: ...means they contain no moving parts Thus it provides users with much greater protection of the data than conventional magnetic disk device Pin Assignment Pin Assignment Pin Assignment Pin Assignment P...

Page 21: ...Type of display adapter installed Number and type of disk drives The CMOS memory is maintained by a battery installed on the PL 10510 board By using the battery all memory in CMOS can be retained when...

Page 22: ...o a different type of CPU Run the AMI Flash program to update the system BIOS Run the BIOS Setup program after you turn on the system On screen instructions explain how to use the program Enter the BI...

Page 23: ...ns you to the main menu 3 3 Menu Options The main menu options of the BIOS Setup program are described in the following and the following sections of this chapter Main For changing the basic system co...

Page 24: ...o move between fields Modify the selected field using the PgUP PgDN keys Some fields let you enter numeric values directly 3 After you have finished with the Advanced setup the or key to switch to oth...

Page 25: ...Mode Watch dog Mode Sec Min Watch dog Timer Set up Watch dog Timer LAN Bypass1 Power off Enabled or Disabled Bypass mode when System Power off LAN Bypass2 Power off Enabled or Disabled Bypass mode wh...

Page 26: ...WIN Enterprises Inc 26...

Page 27: ...WIN Enterprises Inc 27 Serial Port 1 2 Configuration Serial Port Enable or Disable Serial Port COM Change Settings Select an optimal setting for Super IO device...

Page 28: ...WIN Enterprises Inc 28 3 4 3 NCT6791D HW Monitor 3 4 4 Serial port Console Redirection...

Page 29: ...bytes Bits per second Select serial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds Data Bits Set your Data Bits Parity A parity bit c...

Page 30: ...nals VT UTF8 Combo Key Support Enable VT UTF8 Combination Key Support for ANSI VT100 terminals Recorder Mode With this mode enabled only text will be sent This is to capture Terminal data Resolution 1...

Page 31: ...WIN Enterprises Inc 31 Socket 0 CPU Information Active Processor Cores...

Page 32: ...ned with a supporting OS Windows Server 2003 SP1 Windows XP SP2 SuSE Linux 9 2 RedHat Enterprise 3 Update 3 Intel Virtualization Technology When enabled a VMM can utilize the additional hardware capab...

Page 33: ...1 or Gen2 SATA ODD Port No ODD mode HDD or SSD ODD mode ODD SATA Mode 1 IDE Mode 2 AHCI Mode 3 RAID Mode Serial ATA port 0 Enabled or Disabled Serial ATA port 0 Serial ATA port 1 Enabled or Disabled S...

Page 34: ...g Enabled or Disabled 64bit capable Devices to be Decoded in Above 4G Address Space Only if System Supports 64 bit PCI Decoding SR IOV Support Enabled or Disabled SR IOV mode 3 4 8 1 PCI Express Setti...

Page 35: ...Enabled or Disabled PCI Express Device No Snoop option Maximum Payload Set Maximum Payload of PCI Express Device or allow System BIOS to select the value Maximum Read Request Set Maximum Read Request...

Page 36: ...ut Use this item to define number of microseconds software will wait before polling Link Training bit in link status register Value range from 10 to 1000uS Unpopulated Links In order to save power sof...

Page 37: ...s AtomicOp Requests only if Bus Master Enable bit is in the Command Register Set AtomicOp Egress Blocking If supported by hardware and set to Enabled outbound AtomicOp Requests via Egress Ports will b...

Page 38: ...Compliance SOS If supported by hardware and set to Enabled this will force LTSSM to send SKP Ordered Sets between sequences when sending Compliance Pattern or Modified Compliance Pattern Hardware Auto...

Page 39: ...g BIOS services ALWAYS do not allow disabling GA20 this option is useful when any RT code is executed above 1MB Option ROM Messages Set display mode for Option ROM Boot option filter This option contr...

Page 40: ...pport The EHCI ownership change should be claimed by EHCI driver USB Mass Storage Device Configuration Configure the USB Mass Storage Devices USB transfer time out The time out value for Control Bulk...

Page 41: ...WIN Enterprises Inc 41 the delay is taken from Hub descriptor Mass storage devices Scan your USB port device 3 5 Chipset Menu 3 5 1 Chipset North Bridge...

Page 42: ...WIN Enterprises Inc 42 3 5 1 1 Chipset North Bridge Intel IGD Configuration GOP Driver...

Page 43: ...able Enabled or Disabled Integrated Graphics Device Turbo Mode Spread Spectrum clock Enabled or Disabled Spread Spectrum clock 3 5 2 Chipset South Bridge USB 2 0 EHCI Support Enabled or Disabled USB2...

Page 44: ...Password This item allows you to set or change the administrator password The Administrator Password item on top of the screen shows the default Not Installed After you have set a password this item s...

Page 45: ...Use the and keys to adjust the number of seconds to wait for setup activation key Bootup NumLock Stat This item allows you to select On or Off power on state for the NumLock Quiet Boot Enabled or Disa...

Page 46: ...WIN Enterprises Inc 46 Boot Option 1 8 Set the USB boot priority order...

Page 47: ...llowing screen appears Save Changes and Reset Store all changes you made into CMOS and reboot system F4 key can be used for this operation Discard Changes and Reset Discard all changes you made and re...

Page 48: ...and Linux operation system as follows Before installation please check your OS version If your OS is not in the following list please upgrade your OS version OS Version DOS DOS 6 22 Windows Windows 7...

Page 49: ...he LAN driver in the setup CD Please click the Autorun file and install the driver following the procedures 1 Insert the setup CD of PL 10510 into your CD ROM drive 2 Choose the Drivers file to click...

Page 50: ...ler The value range is from 01H to FFH and the related time watchdog timer interval is 1 sec to 255 sec Data Timer interval 00 Disabled 01 1 sec 02 2 sec FF 255 sec If you want to disable the watchdog...

Page 51: ...chdog timer After setting the timer interval value the watchdog timer begins to count down You have to refresh the watchdog timer so that the watchdog timer will return to its initial value otherwise...

Page 52: ...Cat 5 Cable 2M RoHS CB EC5200 01 1 Cross Over 2M Color RoHS CB CO5204 01 1 RJ45 to DB9 2M Cable RoHS CB RJDB91 01 1 VGA CABLE 2mm 15CM RoHS CB IVGA01 00 1 2m null modem cable RoHS CB DB9200 01 1 KB M...

Reviews: