![WimTec SKY Series Assembly And Operating Instructions Manual Download Page 17](http://html.mh-extra.com/html/wimtec/sky-series/sky-series_assembly-and-operating-instructions-manual_984387017.webp)
Washbasin fitting
WimTec SKY
17
EN
SKY
ON
OFF
1 2 3 4 5 6
Configuring the functions
1
Time control
2
Sensitivity control
3
DIP switches
Position of the
sensor ring
3. DIP switches:
s
30
600
Function activation – DIP switch 1 - 6:
DIP switch
Function
Default setting
Description
1
Flushing mode
ON
Page 20
2
Cleaning stop
OFF
Page 21
3
Continuous flow
OFF
Page 22
4
Intelligent automatic flushing
OFF
Page 23
5
Automatic flushing interval
(ON =3 h, OFF =
24 h
)
OFF
Page 24
6
Follow-up time (ON = 5 s, OFF =
3 s
)
OFF
Page 24
Setting controls:
1. Sensivity control
regulates the shut-off
sensitivity of the fitting.
2. Time control
for flushing stop time, default
setting 1 min (setting range
30 s to 10 min).
Rule applies to all controls:
Move counterclockwise to decrea-
se the setting. Move clockwise to
increase the setting.
!