![WimTec SanTec ECO Installation And Operating Instructions Manual Download Page 14](http://html.mh-extra.com/html/wimtec/santec-eco/santec-eco_installation-and-operating-instructions-manual_984378014.webp)
14
Selection of function programme
GB
ATTENTION!
Adjustment of flushing programs only
possible in the first 10 s after initiation
(as soon as battery will be inserted or power
unit will be connected)
Program 1 factory-made pre-adjusted.
For changing the flushing program of an already
adjusted control, the power supply must be
disconnected for at least 60 s, afterwards a new
programming is possible.
1 x . . 2 x . . 3 x . .
Remove hand at the desired program (LED
flashes x times) - the control confirms the
program by flashing twice quickly.
Afterwards there are further 10 s for changing
the flushing program again. After lapse of this
time, the device flashes 3 times quickly and it
changes into normal function.
Establish reflex with the hand (Hold hand 2 cm in
front of the sensor window)
Red LED flashes:
*
Once = Prog. 1
- without continuous
flow
resp.
continuous flow
**
Twice = Prog. 2
- Continuous flow
***
Third = Prog. 3
- Cleaning stop
****
Fourth = Prog. 4
- Continuous flow and
cleaning stop
*****
Fifth = Prog. 5
- Continuous flow for
thermal disinfection, hygiene flush 3 h
******
Sixth = Prog. 6
- Continuous flow for
thermal disinfection, hygiene flush 24 h
*******
Seventh = Prog. 7
- for small washbasins