Kitchen fitting
WimTec VIVA | PUREA
29
EN
VIVA | PUREA
Configurate the functions
E.
Far active range
controller:
Default setting: 25 cm
(adjustable from 10 - 40 cm)
F.
Close active range
controller:
Default setting: 5 cm
(adjustable from 1 - 10 cm)
G.
Time control
DIP 2 - ON: Safety flushing stop
Default setting:
60 s
(adjustable from 10 - 600 s)
DIP 2 - OFF: Flushing stop
Default setting: 25 s
(adjustable from 10 - 60 s)
Regulator controls:
Range-controller:
Serves to adjust the active range of the infrared sensor.
In this area the fitting recognizes the user and the water
flow is released resp. continued.
DIP switches:
DIP switch
Function
Description
1
Non-contact activation
(ON = via far active range /
OFF
1)
= via close active range)
Page 14
2
Non-contact deactivation
(
ON
1)
= via far active range / OFF = via close active range)
Page 15
3
Cleaning stop ON /
OFF
1)
Page 16
4
Interval stagnation rinse (ON = 24 h /
OFF
1)
= 3 h)
Page 17
5
Stagnation rinse ON /
OFF
1)
Page 17
6
Shut-off delay ON = 5 s /
OFF
1)
= 2 s
Page 17
1)
Factory-adjusted functions.
10
300
s
600
450
150
10
25
cm
40
33
17
1
5
cm
10
7
3