Wall tap control
WimTec OCEAN W6
27
EN
PROOF W6
Program description
Switch on
As soon as you enter the
sensor range, the water flow
will start automatically.
(range control configurable
from 15–30 cm)
Switch off
Once you clear the sensor
range or after the configu-
red shut-off delay time has
elapsed, the water will stop.
(DIP switch 6)
Safety flow arrest
After the configured water
arrest time has elapsed, the
water flow will automatically
stop to prevent unintentional
continuous activation.
Fully automatic program mode (default setting):
DIP switch 1=ON, 2=ON
Werkseinstellung:
ON
OFF
1 2 3 4 5 6
ON
OFF
1
2 3 4 5
6
ON
OFF
1
2
3 4 5
6
ON
OFF
1
2
3 4 5
6
ON
OFF
1 2
3
4 5
6
ON
OFF
1 2 3
4
5
6
ON
OFF
1 2 3 4
5
6
ON
OFF
1 2 3 4 5
6
ON
OFF
1
2 3 4 5
6
If your hands frequently leave the sensor range while washing your hands, for example,
causing the water flow to stop prematurely, you can extend the shut-off delay to 5 s.
When using an instantaneous water heater, the configured shut-off delay helps to minimi-
se the number of ignition processes.
DIP switch 6 ON = Extended shut-off delay – 5 s.
DIP switch 6 OFF = Standard shut-off delay – 2 s (default setting).
!