20        Urinal flush valve 

WimTec OCEAN U4

EN

 OCEAN U4

13

12

11

10.

 

Open the integrated stop valve. 

11.

 

If required, adjust the electronics module with the desired 
settings (see p. 16).

12.

 

Position the front plate - perform function check.

13.

 

Secure from below with a screw.

10

ATTENTION!  
Perform the following steps 
in the order indicated!

!

Assembly

Summary of Contents for OCEAN U4 121 131

Page 1: ...OCEAN U4 DE Montage und Bedienungsanleitung EN Assembly and operating instructions ...

Page 2: ...30 V 9 V Glas schwarz Art Nr 121 087 121 124 Glas weiß Art Nr 121 094 121 131 Lieferumfang Sicherheitsglas Frontplatte mit integrierter Elektronik Batteriemodul inkl Batterie oder WimTec Netzteil Montagerahmen Magnet ventil und Befestigungsmaterial Wichtige Installationshinweise Die Montage und Installation darf nur durch einen konzessionierten Fachbetrieb gemäß DIN 1988 ÖVE ÖNORM E 8001 sowie VDE...

Page 3: ...Urinaldruckspüler WimTec OCEAN U4 3 DE OCEAN U4 Seite Technische Daten 4 Maße 5 Legende 6 Funktion 7 Montage 8 Ersatzteile 11 Inhaltsverzeichnis ...

Page 4: ...ium CR P2 Batterielebensdauer 9 V Alkali ca 100 000 Auslösungen max 2 Jahre 6 V Lithium ca 200 000 Auslösungen max 4 Jahre Magnetventil 1 2 6 V Hauptspülung 1 s bis 10 s einstellbar Fließdruck 0 08 bis 0 5 MPa 0 8 bis 5 bar Statischer Druck max 0 8 MPa 8 bar Durchflussmenge gemäß EN 15091 Wasserzulauf R 1 2 IG Wasserablauf R 1 2 AG Werkstoff Frontplatte Sicherheitsglas ESG WimTec OCEAN U4 230 V Wi...

Page 5: ... max 158 25 5 25 5 Fliese Putz 110 5 5 95 103 122 127 Zulauf R 1 2 IG Ablauf R 1 2 AG 230 V B L Maße Montage OK FFB 65 Erwachsene 94 Unterkante Rohbauset B L Bei 230 V Netzbetrieb Elektro Leerverrohrung vorsehen Spannungsversorgung 2 x 0 75 mm2 1 5 mm2 230 V bei Netzausführung Maße in cm ...

Page 6: ... 3 B L Zulauf Ablauf 1 AquaCap Taster zum Aktivieren einer Spülung 2 Spülzeit Regler für die Dauer der Hauptspülung 5 s voreingestellt 1 s bis 10 s einstellbar 3 Anschluss Magnetventil 4 Anschluss Netzteil oder Batteriemodul WimTec OCEAN U4 Frontplatte Vorderseite Rückseite WimTec Rohbauset U2 1 2 4 3 1 5 s 10 3 7 ...

Page 7: ...ktion Hauptspülung durch Tippen auf das Symbol einstellbar von 1 bis 10 s Spülmenge in l 2 0 3 0 4 0 Fließdruck 1 bar 5 5 s 7 0 s 10 0 s 2 bar 4 5 s 5 5 s 7 5 s 3 bar 3 0 s 4 5 s 6 0 s 4 bar 2 5 s 4 0 s 5 5 s 5 bar 2 5 s 4 0 s 5 0 s Spülmengen Übersicht ...

Page 8: ... Abdeckung wieder einsetzen 2 a Vorabsperrung öffnen und Leitung durchspülen danach Vorabsperrung wieder schließen b Schmutzsieb Abdeckung öffnen c Schmutzsieb und Schmutzsieb Abdeckung wieder einsetzen 3 Magnetventiladapter mit Dichtungen einsetzen Flussrichtung beachten 4 Kabel für Spannungsversorgung in das Rohbauset einziehen nur bei 230 V Netzversion 5 Versorgungskabel mit Netzteil verbinden ...

Page 9: ...ahmen ausrichten und festschrauben 8 Magnetventil mit Elektronikmodul verbinden 9 Netzteil bzw Batteriemodul mit Elektronikmodul verbinden und bei Netzversion Spannungszufuhr aktivieren Sicher heitsschließimpuls beim Magnetventil erfolgt 7 9 8 6 ACHTUNG Folgende Schritte unbe dingt in beschriebener Reihenfolge ausführen ...

Page 10: ...sperrung öffnen 11 Falls erforderlich Einstellungen am Elektronikmodul anpassen siehe Seite 6 12 Frontplatte aufsetzen Funktionsprüfung durchführen 13 Mit Schraube von unten sichern 10 ACHTUNG Folgende Schritte unbe dingt in beschriebener Reihenfolge ausführen Montage ...

Page 11: ...123 562 Sanitäroberteil 120 547 Thermostat Adapter 119 770 Schmutzfilter 122 695 O Ring 122 701 Filterabdeckung inkl O Ring 222 074 Dichtung 3 4 5 Stk 125 542 Magnetventil 1 2 6 V 221 053 Anschlussverschraubung Art Nr Bezeichnung 231 380 Batteriemodul 230 086 9 V Alkali Batterie 122 350 Netzteil 122 220 Montagerahmen WimTec OCEAN U4 Frontplatte inkl Elektronikmodul 122 213 Glas schwarz 122 206 Gla...

Page 12: ... V 9 V Black glass Art no 121 087 121 124 White glass Art no 121 094 121 131 Delivery scope Safety glass front plate with integrated electronics battery module incl battery or WimTec power supply mounting frame magnetic valve and mounting material Important installation notes Mounting and installation may only be performed by a qualified service provider in accordance with DIN 1988 ÖVE ÖNORM E 800...

Page 13: ...Urinal flush valve WimTec OCEAN U4 13 EN OCEAN U4 Page Technical data 14 Dimensions 15 Legend 16 Function 17 Assembly 18 Spare parts 21 Table of contents ...

Page 14: ...P2 Battery service life 9 V alkaline approx 100 000 flushing activations max 2 years 6 V lithium approx 200 000 flushing activations max 4 years Magnetic valve 1 2 6 V Main flush adjustable from 1 10 s Flow pressure 0 08 0 5 MPa 0 8 5 bar Static pressure Max 0 8 MPa 8 bar Flow rate according to EN 115091 Water inlet R 1 2 IT Water outlet R 1 2 OT Material Front plate safety glass ESG WimTec OCEAN ...

Page 15: ...5 Tile Plaster 110 5 5 95 103 122 127 Inlet R 1 2 IT Outlet R 1 2 OT 230 V B L Dimensions Assembly OK FFB 65 adults 94 lower edge of flush mount set B L When used in 230 V mains operation provide empty duct for electrical installation Power supply 2 x 0 75 mm2 1 5 mm2 230 V mains version Dimensions in cm ...

Page 16: ...Inlet Outlet 1 AquaCap button for activating a flush 2 Flush time control for the duration of the main flush 5 s preset adjustable from 1 s to 10 s 3 Connector for magnetic valve 4 Connection for power supply or battery module WimTec OCEAN U4 front plate Front side Rear side WimTec U2 flush mount set 1 2 4 3 1 5 s 10 3 7 ...

Page 17: ...nction Main flush by tapping the icon adjustable from 1 10 s Flushing volume overview Flushing volume in l 2 0 3 0 4 0 Flow pressure 1 bar 5 5 s 7 0 s 10 0 s 2 bar 4 5 s 5 5 s 7 5 s 3 bar 3 0 s 4 5 s 6 0 s 4 bar 2 5 s 4 0 s 5 5 s 5 bar 2 5 s 4 0 s 5 0 s ...

Page 18: ...rt dirt filter cover 2 a Open the integrated stop valve and flush the line then close the stop valve again b Open dirt filter cover c Re insert dirt filter and dirt filter cover 3 Insert magnetic valve adapter with gaskets observe direction of flow 4 Feed cable for the power supply into the flush mount set only for 230 V mains version 5 Connect power cable with power supply only for 230 V mains ve...

Page 19: ...rame and securely fasten 8 Connect magnetic valve with electronics module 9 Connect power supply or battery module with the electronics module and in the case of the mains version activate the voltage supply causing the safety locking mechanism of the magnetic valve to activate 7 9 8 6 ATTENTION Perform the following steps in the order indicated ...

Page 20: ...en the integrated stop valve 11 If required adjust the electronics module with the desired settings see p 16 12 Position the front plate perform function check 13 Secure from below with a screw 10 ATTENTION Perform the following steps in the order indicated Assembly ...

Page 21: ... 562 Sanitary top piece 120 547 Thermostat adapter 119 770 Dirt filter 122 695 O ring 122 701 Filter cover incl O ring 222 074 Gasket 3 4 5 pcs 125 542 Magnetic valve 1 2 6 V 221 053 threaded connection piece Art no Designation 231 380 Battery module 230 086 9 V alkaline battery 122 350 Power supply 122 220 Mounting frame WimTec OCEAN U4 front plate incl electronics module 122 213 Black glass 122 ...

Page 22: ......

Page 23: ......

Page 24: ...WimTec Sanitärprodukte GmbH p A 3325 Ferschnitz Freidegg 50 AUSTRIA t 43 0 7473 5000 f 43 0 7473 5000 500 m verkauf wimtec com i www wimtec com www wimtec com Auflage 15 05 2017 Art Nr 1002134 ...

Reviews: