Table 3-1.
Reset (Default) Paramenters
681XXB
MODEL
NUMBER
FREQUENCY PARAMETERS (GHz)
F0
F1
F2
F3
F4
F5
F6
F7
F8
F9
M0
M1
M2
M3
M4
M5
M6
M7
M8
M9
∆
F
68137B
3.5
2.0 20.0 2.0
5.0
8.0 11.0 14.0 17.0 20.0 3.5
2.0 20.0 2.0
5.0
8.0 11.0 14.0 17.0 20.0 1.0
68147B
3.5
2.0 20.0 2.0
5.0
8.0 11.0 14.0 17.0 20.0 3.5
2.0 20.0 2.0
5.0
8.0 11.0 14.0 17.0 20.0 1.0
68153B
3.5
2.0 26.5 2.0
5.0
8.0 11.0 14.0 17.0 20.0 3.5
2.0 26.5 2.0
5.0
8.0 11.0 14.0 17.0 20.0 1.0
68159B
3.5
2.0 26.5 2.0
5.0
8.0 11.0 14.0 17.0 20.0 3.5
2.0 26.5 2.0
5.0
8.0 11.0 14.0 17.0 20.0 1.0
68163B
3.5
2.0 40.0 2.0
5.0
8.0 11.0 14.0 17.0 20.0 3.5
2.0 40.0 2.0
5.0
8.0 11.0 14.0 17.0 20.0 1.0
68169B
3.5
2.0 40.0 2.0
5.0
8.0 11.0 14.0 17.0 20.0 3.5
2.0 40.0 2.0
5.0
8.0 11.0 14.0 17.0 20.0 1.0
681XXB
MODEL
NUMBER
POWER LEVEL PARAMETERS (dBm)
L0
L1
L2
L3
L4
L5
L6
L7
L8
L9
68137B
+1.0
0.0
–1.0
–2.0
–3.0
–4.0
–5.0
–6.0
–7.0
–8.0
68147B
+1.0
0.0
–1.0
–2.0
–3.0
–4.0
–5.0
–6.0
–7.0
–8.0
68153B
+1.0
0.0
–1.0
–2.0
–3.0
–4.0
–5.0
–6.0
–7.0
–8.0
68159B
+1.0
0.0
–1.0
–2.0
–3.0
–4.0
–5.0
–6.0
–7.0
–8.0
68163B
+1.0
0.0
–1.0
–2.0
–3.0
–4.0
–5.0
–6.0
–7.0
–8.0
68169B
+1.0
0.0
–1.0
–2.0
–3.0
–4.0
–5.0
–6.0
–7.0
–8.0
681XXB
MODEL
NUMBER
SWEEP
TIME
STEP SWEEP
LEVEL SWEEP
LEVEL
OFFSET
DWELL TIME
NUMBER OF
STEPS
DWELL TIME
NUMBER OF
STEPS
68137B
50 ms
50 ms
50
50 ms
50
0.0 dB
68147B
50 ms
50 ms
50
50 ms
50
0.0 dB
68153B
50 ms
50 ms
50
50 ms
50
0.0 dB
68159B
50 ms
50 ms
50
50 ms
50
0.0 dB
68163B
50 ms
50 ms
50
50 ms
50
0.0 dB
68169B
50 ms
50 ms
50
50 ms
50
0.0 dB
LOCAL (FRONT
RESET (DEFAULT)
PANEL) OPERATION
PARAMETERS
3-14
681XXB OM