Guidelines for Extension Cords

Use proper extension cord. Make sure your
extension cord is in good condition. When using an
extension cord, be sure to use one heavy enough to
carry the current your product will draw. An undersized
cord will cause a drop in line voltage, resulting in loss
of power and cause overheating. The table below
shows the correct size to use depending on cord
length and nameplate ampere rating. If in doubt, use
the next heavier gauge. The smaller the gauge
number, the heavier the cord.

Be sure your extension cord is properly wired and
in good operating condition. Always replace a
damaged extension cord or have it repaired by a
qualified person before using it.

Protect your extension cords from sharp objects,
excessive heat and damp or wet areas.

In the event of a malfunction or breakdown,
grounding provides the path of least resistance for
electric current and reduces the risk of electric shock.
This tool is equipped with an electric cord that has an
equipment grounding conductor and a grounding plug.
The plug MUST be plugged into a matching
receptacle that is properly installed and grounded in
accordance with ALL local codes and ordinances.

Do not modify the plug provided. If it will not fit the
receptacle, have the proper receptacle installed by
an electrician.

Improper connection of the equipment grounding
conductor can result in risk of electric shock. The
conductor with the green insulation (with or without
yellow stripes) is the equipment grounding conductor. If
repair or replacement of the electric cord or plug is
necessary, DO NOT connect the equipment
grounding conductor to a live terminal.

Check with a qualified electrician or service personnel
if you do not completely understand the grounding
instructions, or if you are not sure the tool is properly
grounded.

Use only 3-wire extension cords that have 3-prong
grounding plugs and 3-pole receptacles that accept
the tool’s plug.

This tool is intended for use on a circuit that has a
receptacle like the one illustrated in Figure A, a 
3-wire electrical plug and receptacle that has a
grounding conductor. If a properly grounded
receptacle is not available, an adapter, Figure B, can
be used to temporarily connect this plug to a
2-contact ungrounded receptacle. The adapter,
Figure B, has a rigid lug extending from it that MUST
be connected to a permanent earth ground, such as
a properly grounded receptacle box. 

Repair or replace damaged or worn cord immediately.

Grounding Prong

Properly Grounded
3-Prong Receptacle

3-Prong Plug

Make Sure This
is Connected to a
Known Ground

2-Prong
Receptacle

Adapter

Grounding Lug

Fig. B

Fig. A

SAFETY

6

Minimum Gauge for Extension Cords (AWG)

(when using 120 Volts only)

Ampere Rating

Total Length of Cord in Feet (meters)

More Than

Not More Than

25' (7.6 m)

50' (15 m)

100' (30.4 m)

150' (45.7 m)

0

6

18

16

16

14

6

10

18

16

14

12

10

12

16

16

14

12

12

16

14

12

Not Recommended

SAVE THESE SAFETY INSTRUCTIONS

Summary of Contents for 17204

Page 1: ...understand all instructions Failure to follow all instructions may result in electric shock fire and or serious injury For your safety 6 Bench Grinder Model No 17204 Operation and Safety Instructions...

Page 2: ...ressing Wheel 12 MAINTENANCE 12 Lubrication 12 Cleaning 12 TROUBLESHOOTING 13 SERVICE 14 LIMITED WARRANTY Wilton Power Tools are warranted against defects in workmanship and material for a period of t...

Page 3: ...s attachments to perform a task that it s not designed to do Wear the Proper Apparel and nonslip footwear when operating power tools Do not wear loose clothing gloves neckties rings bracelets or other...

Page 4: ...of any grinder can result in foreign objects being thrown into your eyes which can result in severe eye damage Glasses or goggles that are not in compliance with ANSI Z87 1 could break resulting in se...

Page 5: ...way Use a separate electrical circuit for your tools This circuit must not be less than a 12 wire and should be protected with a 15 Amp time delayed fuse Before connecting the motor to the power line...

Page 6: ...ult in risk of electric shock The conductor with the green insulation with or without yellow stripes is the equipment grounding conductor If repair or replacement of the electric cord or plug is neces...

Page 7: ...om the operator TOOL REST 10 supports workpiece during operation TOOL REST ARM 10A adjustable to move workpiece closer or away from the grinding wheel 6 x 3 4 INCH GRINDING WHEEL 11A for grinding or s...

Page 8: ...ver use gasoline naphtha acetone lacquer thinner or similar highly volatile solvents to clean the bench grinder UNPACKING AND CHECKING CONTENTS Figure 2 Separate all parts from the packing material Ch...

Page 9: ...des of each eye shield mounting hole 2 Attach the knob 5 3 Tighten the knob 5 until the eye shield is in the desired position Note The eye shield must move freely yet stay in place once it is tightene...

Page 10: ...ed to a work surface or grinder stand 2 Align the mounting holes on the grinder with predrilled holes in a bench or grinder stand 3 Insert bolts through the holes and tighten using washers and nuts no...

Page 11: ...GRINDING 1 Adjust the eye shield 2 Check for 1 16 clearance between the wheel and tool rests and 1 8 clearance between the wheel and the spark arrestors Hand turn the grinding wheel to check alignment...

Page 12: ...on tetrachloride chlorinated solvents ammonia and household detergents containing ammonia WARNING All electrical or mechanical repairs should be attempted only a trained repair technician Use only ide...

Page 13: ...al 5 Short circuit 5 Cord plug or motor need repair call Wilton Customer Service Department Motor fails to develop 1 Low line voltage 1 Check power line for proper voltage full power 2 Faulty motor or...

Page 14: ...nical assistance 1 800 274 6848 parts www wmhtoolgroup com In Canada WMH TOOL GROUP LTD Customer Service 212A Wilkinson Road Brampton Ontario L6T 4M4 CANADA Phone 1 800 689 9928 www wmhtoolgroup com C...