Trouble Shooting 
 

Please note the table for trouble shooting. 
If these steps do not remedy the problem contact your reseller. 
 
 

PROBLEM 

POSSIBLE CAUSE 

SOLUTION 

The battery 
charger does not 
work 

- Faulty input fuse 

- Fluctuating mains voltage 

- Replace the faulty fuse 

- Check the mains connection 

The battery is not 
fully charged   

- Bad battery connection 

- Battery capacity is too large 

- Faulty output fuse 

- Faulty battery 

- Check the battery terminals 

- Connect a battery with smaller capacity 
or use a larger battery charger 

- Replace the faulty fuse 

 

Technical data 
 

Model 

GZL30 

Power supply AC 

230 Volt / 50 Hz 

Output voltage DC 

12 Volt 24 Ampere / 24 Volt 16 Ampere 

Dimension total 

310 mm x 240 mm x 230 mm 

Weight 

7,0 kg 

 
 

 

Summary of Contents for WBL-GZL30

Page 1: ...nstructions for Use WBL GZL30 30561 Battery Charger Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificantly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Page 2: ... for purchasing this quality product To minimize the risk of injury by means of fire or electric shock we urge that our clients take some basic safety precautions when using this device Please read the operation instructions carefully and make sure you have understood its content Always use a grounded power connection with the appropriate mains voltage You can find the corre sponding mains voltage...

Page 3: ...lace the defective fuses with new ones having the same Ampere rating Ensure a constant mains voltage By deep discharged battery with large capacity the overload protection can be activated at the upper charging stages especially at excessive mains voltage In this case charge the battery with a lower current stage shortly before till the overload protection holds If the battery is not used every 4 ...

Page 4: ... to the battery plus connection Connect the battery minus cable of the battery charger to the battery minus connection Pay attention to the stable connection between the battery and the battery charger to ensure a proper function of the battery charger Check the accuracy of the charging voltage stage 2 and the charging setting 4 Turn on the battery charger to start the charging process The battery...

Page 5: ...lTec de http www aoyue eu http www teichtip de Panel description 1 Tragegriff 4 Umschalter Minimaler maximaler Ladestrom 2 Umschalter 12 Volt 24 Volt 5 Sicherung Überhitzungsschutz 3 Eingangssicherung AC 6 Amperemeter Ladeanzeige Circuit diagram 保险丝 过流保护器 ...

Page 6: ...input fuse Fluctuating mains voltage Replace the faulty fuse Check the mains connection The battery is not fully charged Bad battery connection Battery capacity is too large Faulty output fuse Faulty battery Check the battery terminals Connect a battery with smaller capacity or use a larger battery charger Replace the faulty fuse Technical data Model GZL30 Power supply AC 230 Volt 50 Hz Output vol...

Page 7: ...ountries with a separate collection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the correct disposal of this article you protect the environment and the health of your fellow m...

Reviews: