Exploded view and parts list
№
Name
№
Name
1
Filter basket
7
Rubber pads
2
Screw
8
Handle
3
Impeller Chamber
9
Gasket
4
Impeller
10
38 mm (1½
″) outlet
5
O-Ring
11
50 mm (2
″) outlet
6
Motor
12
Outlet fixing nut
Winter care
1. Remove the pump from the water.
2. Clean the pump thoroughly.
3. Check the pump for damage.
4. Store the pump frost-free, if possible, in a container with water.
Caution!
The connection plug must not be immersed.
Troubleshooting
Malfunction
Possible cause
Possible solution
Pump does not turn on
There is no power
Check electrical circuit.
Pump does not displace water
1. Filter basket blocked
1. Clean filter basket.
2. Impeller blocked
2. Clean pump.
Insufficient water displace-
ment
1. Filter basket is blocked
1. Clean filter basket.
2. Excessive loss in the supply
lines
2. Reduce hose lengths to the
minimum required, do not use
unnecessary connecting parts.
The pump turns off after run-
ning for a short time
1. Water temperature too high
1. Ensure that the water temper-
ature does not 35
℃
.
2.Impeller stuck
2. Unplug and plug the power