WilTec 61897 Operation Manual Download Page 3

  

© by WilTec Wildanger Technik GmbH  

Item 61897, 61898 

Seite 3

 

http://www.WilTec.de

 

http://www.aoyue.eu 

  

05 2021

-1

 

http://www.teichtip.de

 

 

Introduction

 

 
Thank you for purchasing this quality product.

 To minimize the risk of injury we urge that our clients 

take some basic safety precautions when using this device. Please read the operation instruc-
tions carefully and make sure you have understood its content.

 

Keep these operation instructions safe. 
 
 

 CAUTION: 

 

 

Perform a visual inspection of the device before each use. Do not use the unit if safety devices 
are damaged or worn out. Never disable safety devices. 

 

Only use the device for the purpose specified in these instructions.  

 

You are responsible for the safety in your work area. 

 

Never repair the cable in case it and/or its plug are damaged and do not use the device. The 
cable has to be replaced with a new one. 

 

The voltage of 230 V AC specified on the type plate of the device must correspond to the exist-
ing mains voltage. 

 

Never lift, transport or attach the device to the mains cable. 

 

Make sure that the electrical plug connections are protected from flood and moisture. 

 

Always disconnect the power plug before performing maintenance or any other work on the unit. 

 

Avoid exposing the device to a direct jet of water. 

 

The operator is responsible for compliance with local safety and installation regulations. Ask a 
qualified electrician if necessary. 

 

If the device should fail, repair work may only be carried out by a qualified electrician. 

 

Make sure that there is no one inside the room while the device is in operation. Ventilate the 
room after the set time has elapsed. 

 

 WARNING: 

 

 

This air unit is not a medical device. Do not terminate or change any medical therapy or medi-
cation without the advice of your physician. Excessive ozone concentrations can cause mucous 
membrane or respiratory irritation. 

 

Read all safety instructions. Failure to follow the safety precautions and instructions may result 
in electric shock, fire, and/or serious injury. 

 

Ensure that there are no individuals in the room while the unit is in operation. Ventilate the room 
after the set time has elapsed. 

 

Keep all safety this manual and instructions for future reference. 

 

 Electrical Connection 

 
The electrical connection is made via a 230 V ~ 50 Hz socket outlet with earthing contact. Fuse protec-
tion at least 10 A. 

 

Summary of Contents for 61897

Page 1: ...ing instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificantly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Page 2: ...service wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Esch...

Page 3: ...g connections are protected from flood and moisture Always disconnect the power plug before performing maintenance or any other work on the unit Avoid exposing the device to a direct jet of water The operator is responsible for compliance with local safety and installation regulations Ask a qualified electrician if necessary If the device should fail repair work may only be carried out by a qualif...

Page 4: ... ozone the old ozone plate needs to be replaced Normally the ozone plate needs to be replaced after working for 8 000 hours Replacing the ozone plate 1 Unplug the unit 2 Lift the plate holder top until it no longer clutches the plate 3 Push the holder top backward until you can take out the plate 4 Slowly and gently take the old plate out 5 Install the new plate in the same slow and gentle manner ...

Page 5: ... after the latest scientific standards Because of the high quality materials and superior craftsmanship you are sure to enjoy it for many years if it is properly maintained Question Is the device difficult to install Answer No just plug it in and set the timer to the time you want the generator to work For even quicker results you can also consider placing the unit high up facing an air intake if ...

Page 6: ...tip de Technical specifications ST 5G 61897 ST 10G 61898 Energy needs 220 240 V 50 60 Hz 1 phase Power W 60 120 Ozone plates number 1 2 Ozone output g h 5 10 Air flow m min 2 8 Noise 35 Cooling down method Air cooling Weight 2 3 Size Ozone plate 9 5 Device 15 5 15 20 5 24 7 21 2 19 0 Package 25 24 20 L W H 32 29 24 L W H ...

Page 7: ...her European countries with a separate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equipment By contributing to the correct disposal of this article you protect the environment and the health of...

Reviews: