Safety instructions

CAUTION:

Perform a regular visual inspection of the device before use. Do not use the device if safety
devices are damaged or worn. Never override safety devices.

Only use the device in accordance with the intended use specified in these operating instruc-
tions.

You are responsible for the safety in the work area

If the cable or the plug is damaged due to external influences, the cable must not be repaired!
It must be exchanged for a new one. This work may only be carried out by a qualified electri-
cian.

The voltage of 230 V (50 Hz) AC stated on the nameplate of the device must correspond to
the existing mains voltage.

Never lift, transport or fasten the device by the power cord.

Make sure that the electrical plug connections are protected from flood and moisture. Pull out
the power plug before working on the device.

Avoid exposing the device to direct water jets.

The operator is responsible for compliance with location-specific safety and installation regula-
tions. If necessary, ask an electrician.

The user must take appropriate measures to prevent consequential damage from flooding of
rooms in the event of malfunctions on the device (e. g. installation of an alarm system, reserve
pump, etc.).

If the device fails, repairs may only be carried out by a qualified electrician.

The device must never run dry or be operated with the suction line fully closed. The manufac-
turer’s guarantee is void for damage to the device caused by running dry.

The device must not be used to operate swimming pools.

The device must not be installed in the drinking water circuit.

The transport of aggressive liquids as well as of abrasive substances (e. g. sand) must be
avoided in any case.

The pump must be protected from frost.

The pump must be protected against dry running.

The device is not to be installed in absorbing wells or pump shafts.

WARNING:

Read carefully all the safety guidelines and instructions. Non-compliance with the safety rules and reg-
ulations can lead to an electric shock, fire and/or serious injury.
Keep the instructions and the safety guidelines in a safe place in case you need them in the future.

© by WilTec Wildanger Technik GmbH 

Item 50741

Page 4 

http://www.WilTec.de
http://www.aoyue.eu

 

11 2020

-1

http://www.teichtip.de

Summary of Contents for 50741

Page 1: ...rating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignif...

Page 2: ...nguages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH K nigsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our...

Page 3: ...ct use of the device Children should be supervised to ensure that they do not play with the device Generalities The macerator waste pump consists of a housing a motor and a pump The pump is suitable f...

Page 4: ...ian The user must take appropriate measures to prevent consequential damage from flooding of rooms in the event of malfunctions on the device e g installation of an alarm system reserve pump etc If th...

Page 5: ...erator the drainage pipe hose must not be directly connected to the macerator but it has to be led coupled via a vented pipe system If connected directly to the macerator the collecting tank may crack...

Page 6: ...hanical elements 1 electric motor 1 turbine Controlling components and safety devices 1 manual override switch 1 check valve by WilTec Wildanger Technik GmbH Item 50741 Page 6 http www WilTec de http...

Page 7: ...possible to the macerator Evacuating toilets and other sanitary units Connect the discharge pipes of the other appliances to the rubber connectors provided and clamp with the pipe For bath or shower w...

Page 8: ...or should start running Before performing this operation check that the opening or inside of the pressure tap chamber are not blocked Installations options In order for the lifting system to switch on...

Page 9: ...the pump Check valve installed the wrong way Reinstall it the right way round starts running and dischar ging accidentally Check valve defect Check the valve Leak in the flushing tank that causes wat...

Page 10: ...is damaged and the automatic activation deactivation does not work prop erly any more With more severe obstructions blockages by solid bodies that have jammed inside the pump body it may be necessary...

Page 11: ...itch in the small black box on the heater or in the sun 4 After drying reassemble the system in reverse order 5 Put the macerator back into operation if the pressure switch is not defective the system...

Page 12: ...12 Rubber feet 13 Seal 14 Steel clamp 15 Evacuation pipe plastic rubber 16 Steel clamp 17 Screw 18 Engine 19 20 21 22 23 24 25 26 27 28 Condenser 29 Pressure switch 50741 1 30 31 32 33 34 35 Transpare...

Page 13: ...by WilTec Wildanger Technik GmbH Item 50741 Page 13 http www WilTec de http www aoyue eu 11 2020 1 http www teichtip de...

Page 14: ...ts out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the corr...

Reviews: