Z 15+ - Timer Type Circulation Pump 

Version 21.07 

 

 

Please read over the operating manual prior to 

installation and keep it for reference. 

V. FAULT ANALYSIS AND ELIMINATION 

Fault   

Main causes 

Elimination methods 

The cold-water pipe is 

filled with hot water 

The temperature sensing function of the jet 

valve has failed 

Replace the jet valve 

The water from the hot 

water side of the faucet is 

not hot 

There are branch pipes 

Add the number of jet valves 

needed 

Forgot to open the cold/hot water angle valve 

at the connection of the jet valve 

Open the angle valve 

The non-return function of the jet valve has 

failed 

Replace the jet valve 

The pump does not run 

The current set time is not turned on 

Turn on the current set time   

The time returns to zero 

when the pump is 

powered on after it is 

powered off 

The built-in button battery of pump is 

exhausted 

Calibrate the time manually 

Note: All the figures given in this manual are schematic diagrams; as the performance of the product is improving continuously, 
the purchased products (including appearance and color, etc.) are subject to physical goods. 

 

END OF SECTION 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

WILO USA LLC 

262-204-6600 

www.wilo-usa.com

 

Wilo Canada Inc. 

403-276-9456 

www.wilo-canada.com

 

Wilo Mexico 

+52 442 167 00 32 

www.wilo-mexico.com

 

 

Summary of Contents for Z 15+

Page 1: ...Installation and Operating Instructions Wilo Z 15 Timed and Constant Temperature Circulating Pump WILO_IOM_Z15 _0821...

Page 2: ...on and keep it for reference The main electrical connection to the pump must be grounded before use It is strictly prohibited to touch the electrical connections of the pump while the pump is in opera...

Page 3: ...RIPTION 1 II TECHNICAL PARAMETERS 2 III INSTALLATION PRECAUTIONS 2 IV HOW TO USE applies to models with timer only models without timer skip to SECTION V FAULT ANALYSIS AND ELIMINATION 4 V FAULT ANALY...

Page 4: ...prohibited for children to use the product unless they are under the supervision of an adult Warning about pressure The system pressure must be less than the maximum pump pressure to operate properly...

Page 5: ...the water must be greater than 32 F and the maximum temperature is 160 F 2 The inlet supply pressure must be higher than 75 PSI to work properly III INSTALLATION PRECAUTIONS For best performance and r...

Page 6: ...5 30min before taking a shower Step 6 Close the cold and hot water angle valves below the tap and observe the signs of cold water inlet outlet and hot water inlet outlet of the temperature sensing byp...

Page 7: ...f time is 1 hour in the timing function Screen function applies to models with timer only From 9 00 p m to 7 00 a m the display interface of water pump will enter the screen rest mode if not operated...

Page 8: ...me calibration function by pressing the Run key or not operating for 20s Timing function Set the running period of water pump press the Timing key the dial indicator lamp becomes flashing and press th...

Page 9: ...he jet valve Open the angle valve The non return function of the jet valve has failed Replace the jet valve The pump does not run The current set time is not turned on Turn on the current set time The...

Reviews: