ENGLISH

(arrow on the upper side of the gyroscope chamber: START-REAC-
TION) to the motor.

– If the phase sequence is incorrect, the red fault indicator will light up

(in the switch box : the red LED “Left” on the SK 545 lights up.

– In this case the 

phase inverter

in the EEC plug should be tightened

and turned by 180° using a suitable screw driver 

(Fig. 1, pos. 

a).

6.2 Adjusting the motor safety switch:

– The functions of the float switch in connection with the switch box

are as follows:
– Float switch up: Pump on
– Float switch down: Pump off

– The float switch’s connecting cable is, as illustrated in Fig. 1, attach-

ed to the 

double T-bracket

on the tubular frame. The connecting

cable is self-clamping 

(Fig. 1, pos. 

).

The attachment height

should be set in such a way that the float switch which hangs down
remains above the lower edge of the pump. The switching hysteresis
between the point of “on” and “off” is determined by the distance
between the float switch and the point at which the cable is at-
tached.

6.3 Operating condition in potentially explosive locations

The pump may only be operated in potentially explosive
locations once it has been ensured that the pump housing is
continually covered by the flow medium. The switch gear
and the float switch are not explosion-proof, operating these

elements in potentially explosive locations is forbidden.

7. Maintenance

Bearings and seals are maintenance-free.
We would nevertheless recommend that the pump be inspected and
maintained once every six months by WILO customer services.

8. Problems, Causes and Solutions

The following problems/faults are indicated by the indicators in / at
the switch box:

– Should the motor overheat: the pump is switched off by the WSK

(the red LED lights up in the switch box “WSK” at SK 545). Once the
cause of the fault has been removed and the pump has been allo-
wed to cool down, the pump can be operated once again following
the brief disconnection of the switch gear from the mains (Pull the
EEC plug).

– Adjusting the motor safety switch: Once the cause of the fault has

been removed and the protective motor switch has been switched
on again, the fault indicator in the switch box goes off.

– Incorrect rotary field : see section 6.2.
– Water inside of the motor: Should water get into the motor the fault

is indicated as follows by red LEDs on the SK 545: “DI WARNING /
DI SHUT-OFF”. Should this fault occur, please contact WILO cus-
tomer services.

See installation and operation instructions for the pump.

If the fault cannot be remedied, please contact your plumbing
and heating specialist or your nearest WILO customer services or
representative.

6

Subject to technical alterations!

Summary of Contents for Wilo-Drain-Mobil TP 100 LT Series

Page 1: ...Wilo Drain Mobil TP 80 LT TP 100 LT Pioneering for You 2 024 242 Ed 02 2007 03 DDD D Einbau und Betriebsanleitung GB Installation and Operating Instructions F Notice de montage et de mise en service...

Page 2: ...Bild 1...

Page 3: ...on of conformity 2 1 General Information 5 2 Safety 5 3 Transport and storage 5 4 Description of product and accessories 5 5 Installation 5 6 Operation 5 7 Maintenance 6 8 Problems Causes and Solution...

Page 4: ...r Elektromagnetisk kompatibilitet 89 336 EEC i denna version 92 31 EEC 93 68 EEC Till mpade harmoniserade normer s rskilt EN 50 081 1 EN 50 082 1 H EK azonoss gi nyilatkozat Ezennel kijelentj k hogy a...

Page 5: ...n Schaltkasten angeschlossen An der Frontplatte des Schaltkastens sind folgende Bedienungs elemente Steuerschalter f r die Einstellungen Hand 0 und Auto matik Betrieb Gr ne Leuchte als Betriebsanzeige...

Page 6: ...ter besitzen keine Ex Schutz Zulassung ein Betrieb dieser Kompo nenten in explosionsgef hrdeter Umgebung ist nicht zul ssig 7 Wartung Lager und Gleitringdichtungen sind wartungsfrei Es wird jedoch emp...

Page 7: ...f the switch box Control switch for setting the following modes Manual O and automatic Green light to indicate that the pump is in operation Red light to indicate a fault Installation and operating in...

Page 8: ...r and the float switch are not explosion proof operating these elements in potentially explosive locations is forbidden 7 Maintenance Bearings and seals are maintenance free We would nevertheless reco...

Page 9: ...tr le de l tanch it annon ant une infiltration d eau dans le moteur le contr le de l ordre des phases SK 545 La pompe et l interrupteur flotteur sont tous deux raccord s au bo tier de commande via un...

Page 10: ...lisation dans un environnement susceptible d explosions Dans un environnement susceptible d explosions la pompe ne peut tre utilis e que si toutes les pr cautions ont t pri ses pour que la pompe soit...

Page 11: ......

Page 12: ......

Reviews: