TROUBLESHOOTING
Do not disassemble the motor housing. This pump has NO repairable internal parts, and disassembling may
cause an oil leak or dangerous electrical wiring conditions.
Picture 2
Table 2: Troubleshooting Common Pump Problems
Problem
Possible Cause
Corrective Action
Pump does not
start or run
1.
Blown fuse
2.
Tripped breaker
3.
Plug disconnected
4.
Corroded plug
5.
Thermal overload
6.
Clogged impeller
7.
Motor failed
8.
Float failed
9.
Water level too low
10.
Tangled switch
1.
Replace fuse
2.
Reset breaker
3.
Secure plug
4.
Clean plug prongs
5.
Unplug for 30 minutes, then plug in
6.
Remove clog
7.
Replace pump
8.
Replace switch
9.
Pump will not turn on unless water level is over the
pump cover and the float switch turns upside down
10.
Reposition the pump and make sure switch moves
freely