• The setting of any thermal tripping that is fitted must correspond to the maxi-
mum current (see name plate) of the speed step at which the pump is being
operated.
Motor protection triping devices
If Wilo tripping units SK 602/SK 622 are present in existing systems, pumps with
full motor protection (WSK) can be connected to them. Perform the mains con-
nection and also the tripping unit connection (refer to the name plate data) in
accordance with the circuit diagrams (Fig. 8 d to 8 g).
TOP-D:
Fig. 8 d:
3~400 V: 100 W P
1
max 550 W, motor terminals in star connection, with WSK,
Fig. 8e:
3~230 V: 100 W P
1
max 550 W, motor terminals in connection, with WSK,
Fig. 8f:
1~230 V: 95 W P
1
max 360 W, motor terminals in connection, with WSK,
capacitor fitted
TOP-S/-SD/-Z:
Fig. 8g:
1~230 V: 320 W P
1
max 400 W, with WSK
Pump with terminal
box type
Tripping
SSM
Fault acknowl-
edgement
TOP-S
TOP-SD
TOP-Z
TOP-I
3~400 V
6
(P
1
max 270 W)
Internal switching off
of a motor phase
-
• Switch off mains
voltage
• Allow motor to
cool down
• Switch on mains
voltage
7
(305 W P
1
max
3125 W)
All-pole switching off
by the integral tripping
electronics
Tripping the SSM is
performed in parallel
with switching off of
the integral tripping
electronics
Manually at the
pump, after the
motor has cooled
down
Pump with terminal
box type
Tripping
SSM
Fault acknowl-
edgement
TOP-D
8
(P
1
max 85 W)
-
-
-
9
(85 W P
1
max
550 W)
WSK and external trip-
ping unit (SK602/
SK622 or other switch/
control unit)
-
Manually at the trip-
ping unit, after the
motor has cooled
down