background image

 

DE EG KONFORMITÄTSERKLÄRUNG

 

EN EC DECLARATION OF CONFORMITY

 

FR DECLARATION DE CONFORMITE CE

 

 
 

Hiermit erklären wir, dass die Partikelseparatoren der Baureihe: 

SiClean 

Herewith, we declare that the particle separators of the series: 

SiClean 

Par le présent, nous déclarons que les séparateur de particules des série: 

SiClean 

(Die Seriennummer ist auf dem Typenschild des Produktes nach Punkten b) & c) von §1.7.4.2 
und §1.7.3 des Anhanges I der Maschinenrichtlinie angegeben.  /   

The serial number is marked on the product site plate according to points b) & c) of §1.7.4.2  
and §1.7.3 of the annex I of the Machinery directive. /   

Le numéro de série est inscrit sur la plaque signalétique du produit en accord avec les points 
b) & c) du §1.7.4.2 et du §1.7.3 de l’annexe I de la Directive Machines.

 

 
 

in der gelieferten Ausführung folgenden einschlägigen Bestimmungen entsprechen:

 

In their delivered state comply with the following relevant directives:

 

dans leur état de livraison sont conformes aux dispositions des directives suivantes:

 

 
 

Maschinenrichtlinie  

2006/42/EG  

Machinery directive  

2006/42/EC 

Directives relatives aux machines 

2006/42/CE 

und gemäß Anhang I, § 1.5.1 die Schutzziele der 

Niederspannungsrichtlinie 2006/95/EG

 eingehalten werden.  /  

and accordingto the  annex I, §. 1.5.1, comply with the safety objectives of the 

Low Voltage Directive 

2006/95/EC.

  

/   

et, suivant l’annexe I, § 1.5.1, respectent  les objectifs de sécurité de la 

Directive Basse Tension 

2006/95/CE

.

 

 

Elektromagnetische Verträglichkeit - Richtlinie 

2004/108/EG 

Electromagnetic compatibility - directive 

2004/108/EC

 

Directive compatibilité électromagnétique  

2004/108/CE 

 

und entsprechender nationaler Gesetzgebung,

 

and with the relevant national legislation,

 

et aux législations nationales les transposant,

sowie auch den Bestimmungen zu folgenden harmonisierten europäischen Normen:

comply also with the following relevant harmonized European standards:
sont également conformes aux dispositions des normes européennes harmonisées suivantes:

EN ISO 12100                 EN 60204-1

Bevollmächtigter für die Zusammenstellung der technischen Unterlagen ist:

Division Pumps and Systems

Person authorized to compile the technical file is:

Quality Manager - PBU Systems

Personne autorisée à constituer le dossier technique:

 

WILO SALMSON FRANCE SAS
80 Bd de l'Industrie - BP 0527
F-53005 Laval Cedex

 

Dortmund, 19.02.2015 
 
 
 

 

 

 
 

Holger Herchenhein 

Senior Vice President - Group Quality 

 
 

 

WILO SE 
Nortkirchenstraße 100 
44263 Dortmund 
Germany 

Document: 2118034.01 
CE-AS-Sh. Nr. 4195655 

Summary of Contents for SiClean 1

Page 1: ...lean Pioneering for You 4 192 808 Ed 01 2015 04 Wilo de Einbau und Betriebsanleitung en Installation and operating instructions fr Notice de montage et de mise en service nl Inbouw en bedieningsvoorsc...

Page 2: ...Fig 1 13 4 13 13 5 5 14 14 14 9 15 12 13 13 3 6 10 1 7 8 14 A 11 16 12 2 13 Fig 2 1 18 8 17 11 4 15 6 230V...

Page 3: ...use 15 3 Transport and interim storage 15 3 1 Transport for installation removal purposes 17 4 Intended use 15 5 Product information 16 5 1 Type key 16 5 2 Technical data 16 5 3 Scope of delivery 16 6...

Page 4: ...he product personnel are not observed this declaration loses its validity 2 Safety These operating instructions contain basic information which must be adhered to during installation operation and mai...

Page 5: ...gether with any internal working operating and safety regulations of the operator are to be complied with 2 5 Safety instructions for the operator This appliance is not intended for use by persons inc...

Page 6: ...arding agent must be taken within the specified period Before installation the product must be kept dry frost free and pro tected from mechanical damage CAUTION Risk of property damage Improper transp...

Page 7: ...equipped with an automatic air vent pos 7 in the upper part to the outlet of the separator This installation and operating instructions describe the complete installation of the SiClean Circulation p...

Page 8: ...ons can result in fatal injury Have the electrical connections established by approved electri cians only in compliance with the applicable regulations Observe the accident prevention regulations CAUT...

Page 9: ...stments and servicing interpose valves on the suction and discharge lines The sludge evacuation pipe must have a full disconnection to outfall at atmospheric pressure The diameter of this pipe must be...

Page 10: ...to section 8 1 General preparation and checking on page 20 have been made switch on the main switch CAUTION Damage to the pump Danger of damage due to incorrect handling Do not let the pump operate wi...

Page 11: ...letely filled open the valve pos 17 down stream of the device Fill up the system Start the circulation pump 10 Faults causes and remedies Safety Maintenance and repair may only be carried out by quali...

Page 12: ...ng of the pump unit Lubricants must be collected The pump components are to be sepa rated according to material metal plastic electronics 1 Use public or private disposal organisations when disposing...

Page 13: ...1 5 1 die Schutzziele der Niederspannungsrichtlinie 2006 95 EG eingehalten werden and accordingto the annex I 1 5 1 comply with the safety objectives of the Low Voltage Directive 2006 95 EC et suivan...

Page 14: ...o ci elektromagnetycznej 2004 108 WE 2004 108 EG pou it harmoniza n normy zejm na stosowanymi normami zharmonizowanymi a w szczeg lno ci viz p edchoz strana patrz poprzednia strona EL TR RO 3 5 7 5 99...

Page 15: ...Hungary Budapest T 36 23 889500 India Pune 411019 T 91 20 27442100 Indonesia Jakarta Timur 13950 T 62 21 7247676 Ireland WILO Ireland T 353 61 227566 Italy Borromeo Milano T 39 25538351 Kazakhstan WI...

Page 16: ...Pioneering for You WILO SE Nortkirchenstra e 100 D 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com...

Reviews: