5
●
The power cord must not be
bent, tied, pulled
or twisted by force.
Electric leakage,
electric shock, or fire
can occur.
TRANSPORTATION AND INSTALLATION
WARNING!
AC220/230V
power cord
or plug
●
Use a rated outlet with
voltage fluctuation
of less than
±
10%.
●
To prevent electric shock,
never plug in a power
cord under wet
conditions.
●
Install the pump where the pump can be
conveniently checked or
repaired after installation.
If the space for the pump
is narrow, make the room
as described on the figure.
●
If the suction height exceeds 10m, it can lead to the
function of abnormal overpressure or damage to the
product. Use under 1kgf/cm
2
(Example: The maximum height from the suction
must be under 10m)
●
Do not connect to town water directly. It can lead to
malfunction or damage to the product.
●
When the pump is highly likely to suck in dust or
foreign material, install a sand filter.
Failure to do so may cause a decline
in pressure and quantity
of pumped water, and
malfunction of the inverter.
●
Install a stop valve on the suction side and the
discharge side of the pump
for easier pump
maintenance.
Stop valve
Stop valve
CAUTION!
Sand filter
●
Before installation, repair or removal
of the pump, the power supply must be
disconnected.
●
Install a breaker of electric leakage
of under 30mA of rated sensitivity
to prevent electric shock.
Breaker
●
Pay special attention to extensions of the power cord.
Any electric leakage or disconnection in the extension
may cause electric shock.
●
How to extend the power cord.
①
Peel off the rubber/plastic insulation of the cable
as long as the connection terminal is.
②
Insulate the connection and cover it with rubber tape.
Then tightly cover it over four times
with friction tape.
●
Don’t clasp the power cord in transportation
and installation. The damaged cord may cause
electric leakage or shock.
Breaker
a concrete floor
ground
Hmax.
10m
over 4kgf/cm
2
water pressure
Summary of Contents for PE-350EA
Page 12: ...WIRING DIAGRAM 12 50Hz PERFORMANCE CURVE PE 410MA 50Hz PE 350EA PE 410MA PE 350EA ...
Page 14: ...MEMO 14 ...
Page 15: ...MEMO 15 ...